Monitoring with the Somanetics INVOS 5100C After Aneurysmal Subarachnoid Hemorrhage
- 22 March 2008
- journal article
- research article
- Published by Springer Nature in Neurocritical Care
- Vol. 9 (3) , 326-331
Abstract
Vasospasm is a major cause of morbidity after subarachnoid hemorrhage (SAH), and current screening techniques (angiography, transcranial Doppler [TCD], and clinical examination) have serious limitations. Brain oximetry is a promising noninvasive tool to detect reduced brain oxygenation from vasospasm. Consecutive SAH patients at high risk for vasospasm were monitored with the INVOS (Somanetics, IL, USA) 5100C cerebral oximeter. We prospectively collected oximeter readings (rO2) with concurrent values for vital signs, intracerebral pressure (ICP), arterial blood gas measurement, and hemoglobin (HGB). Data were prospectively collected every 12 h and at clinical events (angiography, transfusion, etc.). We prospectively recorded clinical history, clinical events, radiology results, and outcomes. Six patients were measured 123 times. rO2 values were correlated with the contralateral side, HGB, blood pressure, and PaO2, but not with ICP or perfusion pressure. There were no measured effects of angiography or transfusion. Patterns relating rO2 readings to clinical, angiographic, or TCD evidence of vasospasm were unclear, and there were no associations with the outcome (cerebral infarction, NIH Stroke Scale, or modified Rankin Scale). INVOS rO2 readings are associated with other factors that relate to cerebral oxygen delivery but seem to be of limited use as a screening tool for vasospasm or cerebral infarction after SAH.Keywords
This publication has 23 references indexed in Scilit:
- Prognostic Factors for Outcome in Patients With Aneurysmal Subarachnoid HemorrhageStroke, 2007
- Safety and Feasibility of Intra-Arterial Nicardipine for the Treatment of Subarachnoid Hemorrhage-Associated Vasospasm: Initial Clinical Experience with High-Dose Infusions2007
- Cerebral infarction associated with acute subarachnoid hemorrhageNeurocritical Care, 2007
- Effects of Acute Treatment With Pravastatin on Cerebral Vasospasm, Autoregulation, and Delayed Ischemic Deficits After Aneurysmal Subarachnoid HemorrhageStroke, 2005
- Cerebral oximetry in out-of-hospital cardiac arrest: standard CPR rarely provides detectable hemoglobin–oxygen saturation to the frontal cortexResuscitation, 2004
- Cerebral Oximetry Monitoring During Carotid Endarterectomy: Effect of Carotid Clamping and ShuntingVascular and Endovascular Surgery, 2003
- Cerebral and peripheral oxygen saturation during red cell transfusionJournal of Surgical Research, 2003
- Impact of Hypoxemia on the Performance of Cerebral Oximeter in Volunteer SubjectsJournal of Neurosurgical Anesthesiology, 2000
- Clinical experience with cerebral oximetry in stroke and cardiac arrestCritical Care Medicine, 2000
- Failure of the INVOS 3100 cerebral oximeter to detect complete absence of cerebral blood flowCritical Care Medicine, 1997