Three-year results from a preclinical implantation study of a long-term resorbable surgical mesh with time-dependent mechanical characteristics
Authors:
Open Access
- 5 October 2011
- journal article
- research article
- Published by Springer Nature in Hernia
- Vol. 16 (2) , 191-197
Abstract
Purpose The purpose of this study was to evaluate the biocompatibility, local tissue effects and performance of a synthetic long-term resorbable test mesh (TIGR® Matrix Surgical Mesh) compared to a non-resorbable polypropylene control mesh following implantation in a sheep model. Methods Full-thickness abdominal wall defects were created in 14 sheep and subsequently repaired using test or control meshes. Sacrifices were made at 4, 9, 15, 24 and 36 months and results in terms of macroscopic observations, histology and collagen analysis are described for 4, 9, 15, 24 and 36 months. Results The overall biocompatibility was good, and equivalent in the test and control meshes while the resorbable mesh was characterized by a collagen deposition more similar to native connective tissue and an increased thickness of the integrating tissue. The control polypropylene mesh provoked a typical chronic inflammation persistent over the 36-month study period. As the resorbable test mesh gradually degraded it was replaced by a newly formed collagen matrix with an increasing ratio of collagen type I/III, indicating a continuous remodeling of the collagen towards a strong connective tissue. After 36 months, the test mesh was fully resorbed and only microscopic implant residues could be found in the tissue. Conclusions This study suggests that the concept of a long-term resorbable mesh with time-dependent mechanical characteristics offers new possibilities for soft tissue repair and reinforcement.Keywords
This publication has 23 references indexed in Scilit:
- Five-year results of a randomised controlled multi-centre study comparing heavy-weight knitted versus low-weight, non-woven polypropylene implants in Lichtenstein hernioplastyHernia, 2011
- Tissue Healing during Degradation of a Long-Lasting Bioresorbable γ-Ray-Sterilised Poly(Lactic Acid) Mesh in the Rat: A 12-Month StudyEuropean Surgical Research, 2010
- In vitro degradation and in vivo biocompatibility of poly(lactic acid) mesh for soft tissue reinforcement in vaginal surgeryJournal of Biomedical Materials Research Part B: Applied Biomaterials, 2007
- Strain-controlled enzymatic cleavage of collagen in loaded matrixBiochemical and Biophysical Research Communications, 2005
- Randomized clinical trial of lightweight composite mesh for Lichtenstein inguinal hernia repairBritish Journal of Surgery, 2004
- Staged Management of Giant Abdominal Wall DefectsAnnals of Surgery, 2003
- The Use of Absorbable Mesh in Splenic Trauma1988
- Preliminary Clinical Experience with the Use of Absorbable Mesh Splenorrhaphy1985
- Differential Staining of Collagens Type I, II and III by Sirius Red and Polarization MicroscopyArchivum histologicum japonicum, 1978
- Collagen polymorphism in experimental granulation tissueBiochemical and Biophysical Research Communications, 1975