New Construction of an Electro-Conjugate Fluid-Jet-Driven Micromotor with an Inner Diameter of 2 mm
Authors:
- 1 June 2006
- journal article
- research article
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part I: Journal of Systems and Control Engineering
- Vol. 220 (4) , 251-256
Abstract
Electro-conjugate fluid (hereafter abbreviated as ECF) is a kind of dielectric fluid that produces a powerful jet flow (ECF jet) between rod-type electrodes in an applied non-uniform static electric field. By using the ECF jet, a new type of micromotor with a simple structure and light weight can be realized. Until now, some types of ECF micromotors have been developed with a 3 mm inner diameter. In this study, a micromotor is fabricated with a 2 mm inner diameter in order to improve the output power density, using the ECF jet. The micromotor was first designed and fabricated; then, the performance of the motor was measured. The experimental results confirm that the micromotor developed here has a higher power density than the micromotors previously developed with 3 mm inner diameter.Keywords
This publication has 3 references indexed in Scilit:
- A Microactuator Using Pressure due to ECF-jet with Needle-type ElectrodesThe Proceedings of JSME annual Conference on Robotics and Mechatronics (Robomec), 2003
- Micromotor Using Electroconjugate Fluid (Fabrication of Inner Diameter 2mm RE type ECF Motor)Journal of Robotics and Mechatronics, 2001
- Dielectric fluid motorsApplied Physics Letters, 1997