Mechanical characterisation of porcine non-intestinal colorectal tissues for innovation in surgical instrument design
- 23 July 2018
- journal article
- research article
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
- Vol. 232 (8) , 796-806
Abstract
This article presents an investigation into the mechanical properties of porcine mesocolon, small intestinal mesentery, fascia, and peritoneum tissues to generate a preliminary database of the mechanical characteristics of these tissues as surrogates for human tissue. No study has mechanically characterised porcine tissue correlates of the mesentery and associated structures. The samples were tested to determine the strength, stretch at failure, and stiffness of each tissue. The results indicated that porcine mesenteric and associated tissues visually resembled corresponding human tissues and had similar tactile characteristics, according to an expert colorectal surgeon. Stiffness values ranged from 0.088 MPa to 6.858 MPa across all tissues, with fascia being the weakest, and mesentery and peritoneum being the strongest. Failure stress values ranged from 0.336 MPa to 6.517 MPa, and failure stretch values ranged from 1.766 to 3.176, across all tissues. These mechanical data can serve as reference baseline data upon which future work can expand.Keywords
Funding Information
- Irish Research Council for Science, Engineering and Technology
This publication has 22 references indexed in Scilit:
- The mesentery: structure, function, and role in diseaseThe Lancet Gastroenterology & Hepatology, 2016
- The impact of long term freezing on the mechanical properties of porcine aortic tissueJournal of the Mechanical Behavior of Biomedical Materials, 2014
- Effects of fabrication on the mechanics, microstructure and micromechanical environment of small intestinal submucosa scaffolds for vascular tissue engineeringJournal of Biomechanics, 2014
- On the mechanical behaviour of carotid artery plaques: the influence of curve-fitting experimental data on numerical model resultsBiomechanics and Modeling in Mechanobiology, 2012
- Ergonomic factors on task performance in laparoscopic surgery trainingApplied Ergonomics, 2012
- A novel experimental procedure based on pure shear testing of dermatome-cut samples applied to porcine skinBiomechanics and Modeling in Mechanobiology, 2010
- Safety, efficacy, and cost-effectiveness of common laparoscopic proceduresSurgical Endoscopy, 2010
- Nanomechanical properties of calcification, fibrous tissue, and hematoma from atherosclerotic plaquesJournal of Biomedical Materials Research Part A, 2008
- The electronic structure and magnetism of the Al/Fe interfacesJournal of Physics and Chemistry of Solids, 2000
- MECHANICAL PROPERTIES OF THE RAT COLON: THE EFFECT OF AGE, SEX AND DIFFERENT CONDITIONS OF STORAGEQuarterly Journal of Experimental Physiology (1981), 1985