DC-DC power converter with a modified control scheme to improve load transient response
Authors:
- 1 September 2012
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 02750473,p. 1-4
Abstract
A modified control scheme is presented in this paper to improve the load transient response of DC-DC power converter by utilizing a previously proposed auxiliary circuit which is capable of operating in both boost mode to discharge the output capacitor during load step down transient, and in buck mode to charge the output capacitor during load step up transient. The proposed modified control scheme for the auxiliary circuit is based on the output voltage peak detection, preset thresholds and zero crossing time information. This scheme achieves significant improvement in load transient response while eliminating the controller performance sensitivity to component values tolerances and complex calculations that could result in undesired transient response. A simulation model is built in MATLAB ® /SIMULINK ® software package to validate the functionalities and advantages of the proposed control scheme.Keywords
This publication has 4 references indexed in Scilit:
- Adaptive digital proportional–integral–derivative controller for power convertersIET Power Electronics, 2012
- A practical control strategy to improve unloading transient response performance for buck converters2011
- Controlled Auxiliary Circuit to Improve the Unloading Transient Response of Buck ConvertersIEEE Transactions on Power Electronics, 2009
- A New Digital Control Algorithm to Achieve Optimal Dynamic Performance in DC-to-DC ConvertersIEEE Transactions on Power Electronics, 2007