Recommendations from the IFCC Working Group on Laboratory Errors and Patient Safety for the Global Adoption of an Essential Quality Indicators Panel in Laboratory Medicine
- 20 November 2025
- journal article
- research article
- Published by Walter de Gruyter GmbH in Clinical Chemistry and Laboratory Medicine (CCLM)
- Vol. 64 (4) , 806-812
Abstract
Objectives: To maximize participation in the international standardization effort, this recommendation aims to update the international guidance of the Working Group on Laboratory Errors and Patient Safety of the International Federation of Clinical Chemistry and Laboratory Medicine by identifying a limited and globally applicable panel of Essential Quality Indicators (QIs) focused on patient safety, clinical outcomes, and harmonization across medical laboratories. Methods: Through a consensus meeting, experts from multiple countries reviewed the IFCC Model of Quality Indicators (MQI) to identify high-priority indicators. Selection prioritized the probability of patient harm, ease of detection, and feasibility of data collection and implementation within national contexts. Results: Six essential QIs covering the total testing process were identified and ratified: (1) rate of misidentified requests (Pre-MisR) and misidentified samples (Pre-MisS); (2) rate of sample rejections (Pre-RejS); (3) rate of hemolysis detected either by automated hemolysis index (Pre-HemI) or visual inspection (Pre-HemV); (4) rate of unacceptable results in External Quality Assessment/Proficiency Testing (Intra-Unac); (5) turnaround time of cardiac troponin at the 90th percentile for the emergency room (Post-TnTAT, Post-TnTAT clin); and (6) rate of incorrect laboratory reports (Post-RectRep). Recommendations on calculation, reporting frequency, and integration into IFCC and national comparison programs are provided. Conclusions: The proposed essential QI panel provides a standardized and feasible framework to support its integration into national comparison programs and the IFCC MQI platform. Its implementation will facilitate data consolidation, strengthen the development of national and global quality specifications, and contribute to continuous improvement in patient safety.Keywords
This publication has 9 references indexed in Scilit:
- Quality indicators: an evolving target for laboratory medicineClinical Chemistry and Laboratory Medicine (CCLM), 2025
- A value-based score for clinical laboratories: promoting the work of the new EFLM committeeClinical Chemistry and Laboratory Medicine (CCLM), 2025
- Establishing quality indicators for point of care glucose testing: recommendations from the Canadian Society for Clinical Chemists Point of Care Testing and Quality Indicators Special Interest GroupsClinical Chemistry and Laboratory Medicine (CCLM), 2023
- Quality indicators in laboratory medicine: state-of-the-art, quality specifications and future strategiesClinical Chemistry and Laboratory Medicine (CCLM), 2022
- Pre-analytical quality indicators in laboratory medicine: Performance of laboratories participating in the IFCC working group “Laboratory Errors and Patient Safety” projectClinica Chimica Acta, 2019
- Defining a roadmap for harmonizing quality indicators in Laboratory Medicine: a consensus statement on behalf of the IFCC Working Group “Laboratory Error and Patient Safety” and EFLM Task and Finish Group “Performance specifications for the extra-analytical phases”Clinical Chemistry and Laboratory Medicine (CCLM), 2017
- Performance criteria and quality indicators for the post-analytical phaseClinical Chemistry and Laboratory Medicine (CCLM), 2015
- Corrigendum to: Performance criteria and quality indicators for the pre-analytical phaseClinical Chemistry and Laboratory Medicine (CCLM), 2015
- Harmonization of quality indicators in laboratory medicine. A preliminary consensusClinical Chemistry and Laboratory Medicine (CCLM), 2014