Correlation between bond strength and nanomechanical properties of adhesive interface
- 25 May 2016
- journal article
- research article
- Published by Springer Nature in Clinical Oral Investigations
- Vol. 21 (4) , 1055-1062
Abstract
Objectives The aims of this study were to evaluate the nanohardness and Young’s modulus of the adhesive-dentin interface and to correlate them with the microtensile bond strength (μTBS) after storage in water for 24 h and 6 months. Methods Eighty human third molar teeth were bonded to composite resin with the Adper Scotchbond Multipurpose (SBMP), Adper Single Bond 2 (SB2), Clearfil SE Bond (CSE) or Clearfil S3 Bond (CS3) adhesive systems and stored in water for 24 h and 6 months. Three bonded teeth were selected for each group for nanoindentation methodology to obtain the nanohardness and modulus values (n = 3), while seven bonded teeth each group were used for μTBS (n = 7). Data were analyzed by two-way ANOVA and Tukey’s test (α = 0.05). Spearman correlation between nanohardness and modulus and μTBS values was also calculated. Results Nanohardness and Young’s modulus values for the dentin and hybrid layer were not significantly different regardless of the adhesive system or water storage periods (p > 0.05). Nanohardness and Young’s modulus values for the adhesive layer were significantly higher for SB2 than for SBMP, CSE, and CS3 systems in both water storage periods. The μTBS values for SBMP and CSE were significantly higher than for SB2 and CS3 in both storage periods. An inverse correlation between Young’s modulus and μTBS was observed for the adhesive layer. Conclusion The water storage periods did not alter nanohardness, Young’s modulus, and μTBS of adhesives. The adhesive layer of SB2 showed the highest nanohardness and Young’s modulus, but the highest dentin bond strength was obtained with SBMP and CSE. Thus, a lower Young’s modulus yielded high bond strength. Clinical relevance The inverse correlation between the Young’s modulus of adhesive systems and dentin bond strength suggests adequate resistance of the adhesive to elastic deformation under stress, which are important properties to predict the success of the dental restoration.Keywords
Funding Information
- Coordination for the Improvement of Higher Education Personnel (CAPES) (1777-2014)
This publication has 44 references indexed in Scilit:
- A characterization of the mechanical behavior of resin-infiltrated dentin using nanoscopic Dynamic Mechanical AnalysisDental Materials, 2013
- Influence of filler addition, storage medium and evaluation time on biaxial flexure strength and modulus of adhesive systemsActa Odontologica Scandinavica, 2011
- Long-term nano-mechanical properties of biomodified dentin–resin interface componentsJournal of Biomechanics, 2011
- Degree of Conversion of Etch-and-Rinse and Self-etch Adhesives Light-cured Using QTH or LEDOperative Dentistry, 2010
- Quality of the interface of primary tooth dentin bonded with antibacterial fluoride-releasing adhesiveJournal of Dentistry, 2010
- Nano-Hardness of Adhesive Interface between Er:YAG Laser-Irradiated Dentin and 4-META/MMA-TBB ResinPhotomedicine and Laser Surgery, 2008
- Effects of a peripheral enamel bond on the long‐term effectiveness of dentin bonding agents exposed to water in vitroJournal of Biomedical Materials Research Part B: Applied Biomaterials, 2007
- Microhardness evaluations of resin-dentin bonding areas by nano-indentation.The Bulletin of Tokyo Dental College, 1999
- Calculation Models for Average Stress and Plastic Deformation Zone Size of Bonding Area in Dentine Bonding SystemsDental Materials Journal, 1995
- An improved technique for determining hardness and elastic modulus using load and displacement sensing indentation experimentsJournal of Materials Research, 1992