Effect of knee flexion on the in situ force distribution in the human anterior cruciate ligament
Authors:
- 1 March 1995
- journal article
- knee and-patella
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 3 (1) , 9-13
Abstract
This study was conducted to evaluate the effect of applied load on the magnitude, direction, and point of tibial intersection of the in situ forces of the anteromedial (AM) and posterolateral (PL) bands of the human anterior cruciate ligament (ACL) at 30° and 90° of knee flexion. An Instron was used to apply a 100 N anterior shear force to 11 human cadaver knees, 6 at 30° of knee flexion and 5 at 90° of knee flexion. A Universal Force Sensor (UFS) recorded the resultant 6 degree‐of freedom (DOF) forces/moments. Each specimen then underwent serial removal of the AM and PL bands. With the knee limited to 1 DOF (anteroposterior), tests were performed before and after each structure was removed. Because the path was identical in each test, the principle of superposition was applied. Thus, the difference between the resultant forces could be attributed to the force carried by the structure just removed. The magnitudes of force in the ACL at 30° and 90° of knee flexion were 114.1±7.4 N and 90.8±8.3 N, respectively (PP<0.05). The direction of the in situ force in the whole ACL as well as its two bands correlated with the anatomic orientation of the ligament. The resultant total ACL force intersected the tibial plateau at the posterolateral aspect of the AM band's insertion at 30° of knee flexion, while at 90°, the force intersection moved posteriorly to the AM/PL border. This research provides new insight into the fundamental force relationships of the ACL and its bundles. In response to an anterior tibial shear force, the AM band of the ACL was the predominant load carrier at both 30° and 90° of knee flexion. However, contrary to carlier reports, the in situ force carried in the PL band increased as knee flexion increased. Further, the tibial intersection of the resultant ACL force moved laterally with knee flexion. These findings confirm the dynamic structure of the ACL that in itself has no isometricity and may also indicate that there is no ideal location in which to position a replacement graft. The use of this methodology with more physiologically unconstrained motion should lead to more definitive clinical conclusions.Keywords
This publication has 27 references indexed in Scilit:
- Determination of the in situ loads on the human anterior cruciate ligamentJournal of Orthopaedic Research, 1993
- The Use of Robotics Technology to Study Human Joint Kinematics: A New MethodologyJournal of Biomechanical Engineering, 1993
- In vivo forces in the anterior cruciate ligament during walking and trotting in a quadrupedJournal of Biomechanics, 1993
- Ligament tension pattern in the flexed knee in combined passive anterior translation and axial rotationJournal of Orthopaedic Research, 1992
- Anterior cruciate ligament reconstruction using quadriceps patellar tendon graftThe American Journal of Sports Medicine, 1991
- Tensions in the anterior and posterior cruciate ligaments of the knee during passive loading: Predicting ligament loads from in situ measurementsJournal of Orthopaedic Research, 1991
- Description and Error Evaluation of an In Vitro Knee Joint Testing SystemJournal of Biomechanical Engineering, 1988
- Design and Performance of a Modified Buckle Transducer for the Measurement of Ligament TensionJournal of Biomechanical Engineering, 1986
- Simultaneous quantitation of knee ligament forcesJournal of Biomechanics, 1983
- The function of the primary ligaments of the knee in anterior-posterior and medial-lateral motionsJournal of Biomechanics, 1980