Setup Error and Effectiveness of Weekly Image-Guided Radiation Therapy of TomoDirect for Early Breast Cancer
Open Access
- 13 February 2015
- journal article
- Published by Korean Cancer Association in Cancer Research and Treatment
- Vol. 47 (4) , 774-780
Abstract
This study investigated setup error and effectiveness of weekly image-guided radiotherapy (IGRT) of TomoDirect for early breast cancer. One hundred and fifty-one breasts of 147 consecutive patients who underwent breast conserving surgery followed by whole breast irradiation using TomoDirect in 2012 and 2013 were evaluated. All patients received weekly IGRT. The weekly setup errors from simulation to each treatment in reference to chest wall and surgical clips were measured. Random, systemic, and 3-dimensional setup errors were assessed. Extensive setup error was defined as 5 mm above the margin in any directions. All mean errors were within 3 mm of all directions. The mean angle of gantry shifts was 0.6°. The mean value of absolute 3-dimensional setup error was 4.67 mm. In multivariate analysis, breast size (odds ratio, 2.82; 95% confidence interval, 1.00 to 7.90) was a significant factor for extensive error. The largest significant deviation of setup error was observed in the first week of radiotherapy (p < 0.001) and the deviations gradually decreased with time. The deviation of setup error was 5.68 mm in the first week and within 5 mm after the second week. In this study, there was a significant association between breast size and significant setup error in breast cancer patients who received TomoDirect. The largest deviation occurred in the first week of treatment. Therefore, patients with large breasts should be closely observed on every fraction and fastidious attention is required in the first fraction of IGRT.Keywords
Funding Information
- Korea Breast Cancer Foundation
This publication has 21 references indexed in Scilit:
- Image-guided volumetric modulated arc therapy for breast cancer: a feasibility study and plan comparison with three-dimensional conformal and intensity-modulated radiotherapyBritish Journal of Radiology, 2013
- Intensity-modulated and hypofractionated simultaneous integrated boost adjuvant breast radiation employing statics ports of tomotherapy (TomoDirect): a prospective phase II trialJournal of Cancer Research and Clinical Oncology, 2013
- Intensity-modulated adjuvant whole breast radiation delivered with static angle tomotherapy (TomoDirect): a prospective case seriesJournal of Cancer Research and Clinical Oncology, 2013
- A comparative dosimetric study for treating left-sided breast cancer for small breast size using five different radiotherapy techniques: conventional tangential field, filed-in-filed, Tangential-IMRT, Multi-beam IMRT and VMATRadiation Oncology, 2013
- Effect of radiotherapy after breast-conserving surgery on 10-year recurrence and 15-year breast cancer death: meta-analysis of individual patient data for 10 801 women in 17 randomised trialsThe Lancet, 2011
- NSABP B-39, RTOG 0413: A Randomized Phase III Study of conventional whole breast irradiation versus partial breast irradiation for women with stage 0, I, or II breast cancer.2006
- Effects of radiotherapy and of differences in the extent of surgery for early breast cancer on local recurrence and 15-year survival: an overview of the randomised trialsThe Lancet, 2005
- Optimizing breast cancer treatment efficacy with intensity-modulated radiotherapyInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2002
- Twenty-Year Follow-up of a Randomized Study Comparing Breast-Conserving Surgery with Radical Mastectomy for Early Breast CancerThe New England journal of medicine, 2002
- A comparison of different intensity modulation treatment techniques for tangential breast irradiationInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 1999