Development and characterization of a wingless ICPC HPGe detector with thin amorphous-Ge contacts
Open Access
- 1 November 2026
- journal article
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (11) , P11004
Abstract
High-purity germanium (HPGe) detectors with thin amorphous-germanium (a-Ge) contacts can provide bipolar charge blocking and surface passivation while minimizing contact-related inactive thickness. We report the fabrication and characterization of a p-type inverted coaxial point-contact (ICPC) HPGe detector using thin a-Ge contacts in a wingless geometry that avoids the protective wing structure used in our previous prototype. The detector was fabricated from a USD-grown, zone-refined HPGe crystal and has a mass of 20.0 g. With the temperature controller set to 77 K, the detector exhibited picoampere-scale leakage current and an operational depletion voltage of approximately 440 V. A representative monitored temperature of approximately 76.3 K was recorded during detector characterization. Gamma-ray spectroscopy yielded energy resolutions of 1.8 keV FWHM at 59.5 keV and 3.2 keV FWHM at 662 keV. The calibrated charge-injection method gave a pulser-derived effective capacitance of 0.496 pF, compared with the simulated intrinsic detector capacitance of 0.488 pF obtained using SolidStateDetectors.jl . With a 241 Am source positioned inside the detector bore, the detector showed a source-correlated excess current and a broad degraded-alpha continuum centered near 3558 keV, demonstrating sensitivity to near-surface interactions. Because the source encapsulation, intervening materials, and near-surface charge-collection response were not independently characterized, the continuum is not used to infer a unique dead-layer thickness or energy-loss mechanism. The principal result is successful fabrication and stable sub-pF operation of a 20-g wingless thin-contact ICPC prototype.Keywords
This publication has 19 references indexed in Scilit:
- Evidence of cluster dipole states in germanium detectors operating at temperatures below 10 KAIP Advances, 2022
- Effect of front, lateral and back dead layer thicknesses of a HPGe detector on full energy peak efficiencyNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2022
- Nuclear Data Sheets for A = 241Nuclear Data Sheets, 2015
- Germanium Detectors in Homeland Security at PNNLJournal of Physics: Conference Series, 2015
- Leakage current in high-purity germanium detectors with amorphous semiconductor contactsNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2015
- Determination of dead-layer variation in HPGe detectorsApplied Radiation and Isotopes, 2014
- Dead-layer thickness effect for gamma spectra measured in an HPGe p-type detectorNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2011
- A Pulse Shape Analysis technique for the MAJORANA experimentNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2010
- Amorphous-semiconductor-contact germanium-based detectors for gamma-ray imaging and spectroscopyNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2007
- HPGe detectors for low-temperature nuclear orientationNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2004