RAB-Plate versus Sliding Hip Screw for Unstable Trochanteric Hip Fractures: Stability of the Fixation and Modes of Failure???Radiographic Analysis of 218 Fractures
Authors:
- Robert BuciutoRBRobert Buciuto
- Richard HammerRHRichard Hammer
- 1 March 2001
- journal article
- clinical trial
- Published by Wolters Kluwer Health in The Journal of Trauma: Injury, Infection, and Critical Care
- Vol. 50 (3) , 545-550
Abstract
The sliding hip screw has gained considerable acceptance in the treatment of unstable trochanteric fractures. However, the new type of 120 degrees fixed angle blade-plate with a buttress rod (RAB-plate) showed encouraging clinical results. The purpose of this study was to assess stability of fixation and analyze modes of failure in unstable trochanteric hip fractures treated with these devices. A retrospective radiographic review of 218 unstable fractures was performed. Linear and angular displacements of the major fragments and implant migration into the femoral head during healing were assessed. Additionally, adequacy of the reduction and the location of the implant within the femoral head as predictors of fixation failure were evaluated. The postreduction neck-shaft angle was maintained in the majority of the fractures in both groups. However, there was a significantly higher incidence of varus angulation by 10 degrees or more by the completion of healing among fractures treated with the sliding hip screw (p = 0.04). There was no statistically significant difference in vertical migration of the device into the femoral head between the implants used (p = 0.3). There was a significant relationship between failure of the fixation and varus reduction (p = 0.04) as well as screw/neck angle deviation more than 20 degrees in the lateral projection (p = 0.005) or if the implant was in a superior or posterior position (p = 0.02). The RAB-plate provided a more stable fixation, especially with regard to maintained postoperative alignment. However, positive predictors for fixation failure were identical for both devices. Here, the screw/neck angle deviation has had the strongest significance for prediction of fixation failure.Keywords
This publication has 26 references indexed in Scilit:
- A Reinforced Rigid Fixation Device for Unstable Intertrochanteric FracturesClinical Orthopaedics and Related Research, 1999
- Trochanteric hip fractures Fixation failure commoner with femoral medialization, a comparison of 101 casesActa Orthopaedica, 1996
- Gamma nail vs compression screw for trochanteric femoral fractures: 15 reoperations in a prospective, randomized study of 378 patientsActa Orthopaedica, 1994
- Healing Complications After Internal Fixation of Trochanteric Hip Fractures: The Prognostic Value of OsteoporosisJournal of Orthopaedic Trauma, 1993
- Valgus reduction of trochanteric fracturesInjury, 1993
- Trochanteric FracturesClinical Orthopaedics and Related Research, 1990
- Sliding hip screws: modes of failureInjury, 1989
- Consumption of hospital resources for femoral neck fractureActa Orthopaedica, 1988
- Instability of trochanteric hip fractures following internal fixation: A radiographic comparison of the Richards sliding screw-plate and the McLaughlin nail-plateActa Orthopaedica, 1984
- Unstable Trochanteric Fractures:A Comparative Analysis of Four Methods of Internal FixationActa Orthopaedica, 1980