A Flexible 202-Channel Epidural ECoG Array With PEDOT: PSS Coated Electrodes for Chronic Recording of the Visual Cortex
- 12 November 2018
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 19 (3) , 820-825
Abstract
Electrocorticography (ECoG) electrode arrays for epidural implantation allow establishing neural interfaces, which promote investigation of complex distributed brain functions and development of neuroprosthetic systems, while having reduced invasiveness in comparison to intracortical or subdural electrode placement. In this work, we present the design, fabrication, and both in-vitro and in-vivo evaluation of a flexible ECoG array with 202 closely spaced electrodes of 560 μm diameter, each coated with the polymer poly(3,4-ethylenedioxythiophene): polystyrene sulfonate (PEDOT: PSS) for chronic recording in two visual cortical areas V1 and V4 of macaque monkeys. The specific layout of the array provides a close fit to the curved surface of the brain. We confirm its chronic recording functionality in-vivo by estimating visual receptive fields for the individual electrodes.Keywords
Funding Information
- German Excellence Initiative via the Creative Unit I-See “The Artificial Eye: Chronic Wireless Interface to the Visual Cortex”
- Priority Program 1665 “Resolving and Manipulating Neuronal Networks in the Mammalian Brain - From Correlative to Causal Analysis” of the DFG (LA 1471/11-2, KR 1844/2-2)
This publication has 19 references indexed in Scilit:
- Decoding of motor intentions from epidural ECoG recordings in severely paralyzed chronic stroke patientsJournal of Neural Engineering, 2014
- Improving brain–machine interface performance by decoding intended future movementsJournal of Neural Engineering, 2013
- Biocompatibility of intracortical microelectrodes: current status and future prospectsFrontiers in Neuroengineering, 2010
- A MEMS-based flexible multichannel ECoG-electrode arrayJournal of Neural Engineering, 2009
- Poly(3,4-ethylene dioxythiophene) (PEDOT) as a micro-neural interface material for electrostimulationFrontiers in Neuroengineering, 2009
- Neural Stimulation and Recording ElectrodesAnnual Review of Biomedical Engineering, 2008
- Effects of insertion conditions on tissue strain and vascular damage during neuroprosthetic device insertionJournal of Neural Engineering, 2006
- Chronic neural recordings using silicon microelectrode arrays electrochemically deposited with a poly(3,4-ethylenedioxythiophene) (PEDOT) filmJournal of Neural Engineering, 2006
- The Application of Implant Technology for Cybernetic SystemsArchives of Neurology, 2003
- Visual sensations produced by intracortical microstimulation of the human occipital cortexMedical & Biological Engineering & Computing, 1990