A Novel Optical Assay System for Bilirubin Concentration Measurement in Whole Blood
Open Access
- 13 September 2021
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 69 (2) , 983-990
Abstract
As a biomarker for liver disease, bilirubin has been utilized in prognostic scoring systems for cirrhosis. While laboratory-based methods are used to determine bilirubin levels in clinical settings, they do not readily lend themselves to applications outside of hospitals. Consequently, bilirubin monitoring for cirrhotic patients is often performed only intermittently; thus, episodes requiring clinical interventions could be missed. This work investigates the feasibility of measuring bilirubin concentration in whole porcine blood samples using dual-wavelength transmission measurement. A compact and low-cost dual-wavelength transmission measurement setup is developed and optimized to measure whole blood bilirubin concentrations. Using small volumes of whole porcine blood (72 µL), we measured the bilirubin concentration within a range corresponding to healthy individuals and cirrhotic patients (1.2–30 mg/dL). We demonstrate that bilirubin levels can be estimated with a positive correlation (R-square > 0.95) and an accuracy of ±1.7 mg/dL, with higher reliability in cirrhotic bilirubin concentrations (> 4 mg/dL) – critical for high-risk patients. The optical and electronic components utilized are economical and can be readily integrated into a miniature, low-cost, and user-friendly system. This could provide a pathway for point-of-care monitoring of blood bilirubin outside of medical facilities (e.g., patient's home).Keywords
All Related Versions
Funding Information
- Australian Research Council (LP160101052)
- National Health and Medical Research Council Early Career Fellowship (GNT1123030)
- NHMRC Development (GNT1139340)
- Victorian Government Operational Infrastructure Support Program
This publication has 33 references indexed in Scilit:
- Multi-wavelength spectrophotometric analysis for detection of xanthochromia in cerebrospinal fluid and accuracy for the diagnosis of subarachnoid hemorrhageClinica Chimica Acta, 2013
- Evaluation of skin and subcutaneous tissue thickness at insulin injection sites in Indian, insulin naïve, type-2 diabetic adult populationIndian Journal of Endocrinology and Metabolism, 2013
- Photoacoustic microscopyLaser & Photonics Reviews, 2013
- Important predictor of mortality in patients with end-stage liver diseaseClinical and Molecular Hepatology, 2013
- Bilistick: A Low-Cost Point-of-Care System to Measure Total Plasma BilirubinNeonatology, 2012
- Diurnal variation of hematology parameters in healthy young males: The Bispebjerg study of diurnal variationsScandinavian Journal of Clinical and Laboratory Investigation, 2011
- Review: Bilirubin pKa studies; new models and theories indicate high pKa values in water, dimethylformamide and DMSOBMC Biochemistry, 2010
- Bilirubin Measurement for Neonates: Comparison of 9 Frequently Used MethodsPediatrics, 2006
- Dual‐Wavelength SpectrophotometryAngewandte Chemie International Edition, 1976
- Dual-wavelength spectrophotometryAnalytica Chimica Acta, 1969