Awareness of Racial Bias in Pulse Oximetry among Practicing Neonatologists: A Cross-Sectional Survey
Authors:
- Patrick J. MaherPMPatrick J. Maher
- Neha GoelNGNeha Goel
- Carol R. HorowitzCHCarol R. Horowitz
- Mariana G. FigueiroMFMariana G. Figueiro
- Lynne D. RichardsonLRLynne D. Richardson
- Mark ReaMRMark Rea
- 18 November 2025
- journal article
- Published by S. Karger AG in Neonatology
- Vol. 123 (1) , 1-5
Abstract
Introduction: Pulse oximeters may systematically overestimate arterial oxygen saturation in neonates with darker skin pigmentation. We performed a survey in practicing neonatologists to explore knowledge of this bias and the implications for clinical care. Methods: An email survey was distributed assessing knowledge of melanin-related pulse oximeter bias, perceived clinical significance, and communication practices. Responses were compared to data from emergency medicine (EM) clinicians. Results: Survey results from 120 neonatologists showed that 45.0% agreed that bias exists in pulse oximetry based on skin pigmentation. Among respondents aware of the bias, less than half correctly identified its direction. Most clinicians reported no change in clinical management for dark-skinned neonates. Compared to EM clinicians, neonatologists changed clinical practice less often and rated discussions with families as less important. Conclusion: Awareness of pulse oximetry bias related to skin pigmentation remains limited among neonatologists, with low rates of modification to daily clinical practice.Keywords
This publication has 10 references indexed in Scilit:
- Light source spectra and higher measurement uncertainty in pulse oximeter readings for individuals with darker skin pigmentationBritish Journal of Anaesthesia, 2025
- Race and Pulse Oximetry in Infants With Single Ventricles Undergoing Stage 1 PalliationJAMA Network Open, 2024
- Survey in emergency medicine of skin pigmentation bias in pulse oximetersThe American Journal of Emergency Medicine, 2024
- Racial and skin color mediated disparities in pulse oximetry in infants and young childrenPaediatric Respiratory Reviews, 2024
- Racial bias and reproducibility in pulse oximetry among medical and surgical inpatients in general care in the Veterans Health Administration 2013-19: multicenter, retrospective cohort studyBMJ, 2022
- Association of Race With Pulse Oximetry Accuracy in Hospitalized ChildrenJAMA Network Open, 2022
- Analysis of Discrepancies Between Pulse Oximetry and Arterial Oxygen Saturation Measurements by Race and Ethnicity and Association With Organ Dysfunction and MortalityJAMA Network Open, 2021
- Racial discrepancy in pulse oximeter accuracy in preterm infantsJournal of Perinatology, 2021
- Racial Bias in Pulse Oximetry MeasurementNew England Journal of Medicine, 2020
- The Effect of Skin Pigmentation on the Accuracy of Pulse Oximetry in Infants with HypoxemiaThe Journal of Pediatrics, 2017