Heidelberg Retinal Tomograph (HRT 2) Parameters in Primary Open Angle Glaucoma and Primary Angle Closure Glaucoma: A Comparative Study in an Indian Population
Authors:
- 1 January 2006
- journal article
- research article
- Published by Taylor & Francis in Ophthalmic Epidemiology
- Vol. 13 (5) , 343-350
Abstract
Aims: To compare the Heidelberg Retinal Tomograph (HRT 2) parameters in patients with primary open angle glaucoma (POAG) and primary angle closure glaucoma (PACG) in an Indian population. Materials and Methods: Two groups of patients were recruited: group I comprised 78 eyes (78 patients) with POAG and group II 58 eyes (58 patients) with PACG. Based on visual field defects detected by automated perimetry, the groups were further classified into early, moderate, and severe glaucoma. All patients underwent a complete ophthalmic examination as well as an HRT 2 examination. The HRT parameters for the two groups were compared and the sensitivity and specificity of the parameters calculated. Results: All HRT parameters were similar in both groups: 85.9% (95% CI: 78.2, 93.6) of POAG and 81% (95% CI: 72.3, 89.3) of PACG had a positive F. S. Mikeleberg (FSM) discriminant function. Considering outside normal limits and borderline as abnormal, the Moorefield regression analysis had 83.3% (95% CI: 75, 91.6) sensitivity in POAG and 75.9% (95% CI: 64.9, 86.9) in PACG. In early POAG, the FSM discriminant function had a sensitivity of 74.3% (95% CI: 59.8, 88.8) compared to 58.3% (95% CI: 38.9, 77.7) for early PACG. The cup shape measure (p = 0.018) and the Moorfield regression analysis (p = 0.011) had significantly higher sensitivity for early POAG than for early PACG: cup shape measure sensitivity 62.9% (95% CI 46.9, 78.9) for early POAG versus 33.3% (95% CI: 14.4, 52.2) for early PACG and Moorefield regression analysis 74.3% (95% CI: 59.8, 88.8) versus 45.8% (95% CI: 39.9, 65.7). Conclusions: HRT has moderate sensitivity in the detection of damage leading to glaucomatous field defects. The sensitivity of HRT for early PACG appears to be less than that for early POAG. This may indicate a difference in pathophysiology.Keywords
This publication has 25 references indexed in Scilit:
- Angle-closure glaucoma in an urban population in southern indiaOphthalmology, 2000
- Heidelberg retina tomography and optical coherence tomography in normal, ocular-hypertensive, and glaucomatous eyes11The authors have no financial interest in any device or technique described in this article.Ophthalmology, 1999
- Optic disc topographic measurements after pupil dilationOphthalmology, 1999
- Optic nerve head and retinal nerve fiber layer analysisOphthalmology, 1999
- Identification of early glaucoma cases with the scanning laser ophthalmoscope11The authors have no proprietary interest in the development or marketing of this or a competing instrument.Ophthalmology, 1998
- Number of people with glaucoma worldwide.British Journal of Ophthalmology, 1996
- Correlation of Visual Field With Scanning Confocal Laser Optic Disc Measurements in GlaucomaArchives of Ophthalmology (1950), 1995
- Multiple significance tests: the Bonferroni methodBMJ, 1995
- Biostatistical evidence for two distinct chronic open angle glaucoma populations.British Journal of Ophthalmology, 1990
- FLUORESCEIN ANGIOGRAPHY OF THE OPTIC DISC AND THE PERIPAPILLARY AREA IN CHRONIC GLAUCOMAActa Ophthalmologica, 1970