Cerebral aneurysm treatment using flow-diverting stents: in-vivo visualization of flow alterations by parametric colour coding to predict aneurysmal occlusion: preliminary results
Authors:
- 17 October 2014
- journal article
- Published by Springer Nature in European Radiology
- Vol. 25 (2) , 428-435
Abstract
After deployment of flow-diverting stents (FDS), complete aneurysm occlusion is not predictable. This study investigated whether parametric colour coding (PCC) could allow in vivo visualization of flow alterations induced by FDS and identify favourable or adverse flow modulations. Thirty-six patients treated by FDS were analyzed. Preinterventional and postinterventional DSA-series were postprocessed by PCC and time-density curves (TDCs) were calculated. The parameters aneurysmal inflow, outflow, and relative time-to-peak (rTTP) were calculated. Preinterventional and postinterventional values were compared and related to occlusion rate. Postinterventional inflow showed a mean reduction of 37 %, outflow of 51 %, and rTTP a prolongation of 82 %. Saccular aneurysm occlusion occurred if a reduction of at least 15 % was achieved for inflow and 35 % for outflow (sensitivity: 89 %, specificity: 82 %). Unchanged outflow and a slightly prolonged rTTP were associated with growth in one fusiform aneurysm. PCC allows visualization of flow alterations after FDS treatment, illustrating “flow diverting effects” by the TDC shape and indicating mainly aneurysmal outflow and lesser inflow changes. Quantifiable parameters (inflow, outflow, rTTP) can be obtained, thresholds for predicting aneurysm occlusion determined, and adverse flow modulations assumed. As a rapid intraprocedural tool, PCC might support the decision to implant more than one FDS. • After deployment of a flow-diverting stent, complete aneurysm occlusion is unpredictable. • Parametric colour coding offers new options for visualizing in vivo flow alterations non-invasively. • Quantifiable parameters, i.e., aneurysmal inflow/outflow can be obtained allowing prognostic stratification. • Rapid, intraprocedural application allows treatment monitoring, potentially contributing to patient safety.Keywords
This publication has 30 references indexed in Scilit:
- Endovascular Treatment of Intracranial Aneurysms With Flow DivertersStroke, 2013
- Immediate and Midterm Results following Treatment of Recently Ruptured Intracranial Aneurysms with the Pipeline Embolization DeviceAmerican Journal of Neuroradiology, 2011
- Pipeline embolization device (PED) for neurovascular reconstruction: initial experience in the treatment of 101 intracranial aneurysms and dissectionsNeuroradiology, 2011
- Impact of Stents and Flow Diverters on Hemodynamics in Idealized Aneurysm ModelsJournal of Biomechanical Engineering, 2011
- The adverse effects of flow-diverter stent-like devices on the flow pattern of saccular intracranial aneurysm models: computational fluid dynamics studyActa Neurochirurgica, 2011
- Reply:American Journal of Neuroradiology, 2010
- Quantitative Characterization of the Hemodynamic Environment in Ruptured and Unruptured Brain AneurysmsAmerican Journal of Neuroradiology, 2010
- Association of Hemodynamic Characteristics and Cerebral Aneurysm RuptureAmerican Journal of Neuroradiology, 2010
- Parametric Color Coding of Digital Subtraction AngiographyAmerican Journal of Neuroradiology, 2010
- Correlation Between Angiographic and Particle Image Velocimetry Quantifications of Flow Diverters in an In Vitro Model of Elastase-Induced Rabbit AneurysmsJournal of Biomechanical Engineering, 2009