Anodized titanium and stainless steel in contact with CFRP: An electrochemical approach considering galvanic corrosion
- 2 March 2007
- journal article
- research article
- Published by Wiley in Journal of Biomedical Materials Research Part A
- Vol. 82A (4) , 936-946
Abstract
The combination of different materials in an implant gives the opportunity to better fulfill the requirements that are needed to improve the healing process. However, using different materials increases the risk of galvanic coupling corrosion. In this study, coupling effects of gold‐anodized titanium, stainless steel for biomedical applications, carbon fiber reinforced polyetheretherketone (CFRP), and CFRP containing tantalum fibers are investigated electrochemically and by long‐term immersion experiments in simulated body fluid (SBF). Potentiodynamic polarization experiments (i/E curves) and electrochemical impedance spectroscopy (EIS) of the separated materials showed a passive behavior of the metallic samples. Anodized titanium showed no corrosion attacks, whereas stainless steel is highly susceptibility for localized corrosion. On the other side, an active dissolution behavior of both of the CFRPs in the given environment could be determined, leading to delaminating of the carbon fibers from the matrix. Long‐term immersion experiments were carried out using a set‐up especially developed to simulate coupling conditions of a point contact fixator system (PC‐Fix) in a biological environment. Electrochemical data were acquired in situ during the whole immersion time. The results of the immersion experiments correlate with the findings of the electrochemical investigation. Localized corrosion attacks were found on stainless steel, whereas anodized titanium showed no corrosion attacks. No significant differences between the two CFRP types could be found. Galvanic coupling corrosion in combination with crevice conditions and possible corrosion mechanisms are discussed. © 2007 Wiley Periodicals, Inc. JBiomed Mater Res, 2007Keywords
This publication has 13 references indexed in Scilit:
- Composite Implant for Bone ReplacementJournal of Composite Materials, 1997
- Fretting corrosion accelerates crevice corrosion of modular hip tapersJournal of Applied Biomaterials, 1995
- Basic concepts relevant to the design and development of the point Contact Fixator (PC-Fix)Injury, 1995
- Long‐term durability of the interface in FRP composites after exposure to simulated physiologic saline environmentsJournal of Biomedical Materials Research, 1994
- Biological response to chopped‐carbon‐fiber‐reinforced peekJournal of Biomedical Materials Research, 1992
- Electrochemistry of galvanic couples between carbon and common metallic biomaterials in the presence of crevicesBiomaterials, 1990
- In vitro biocompatibility of polyetheretherketone and polysulfone compositesJournal of Biomedical Materials Research, 1990
- Titanium: The implant material of todayJournal of Materials Science, 1987
- Corrosive effect of carbon-fibre reinforced plastic on stainless-steel screws during implantation into manJournal of Medical Engineering & Technology, 1983
- The anodic polarization of titanium in halide solutionsCorrosion Science, 1964