Preclinical 4D-flow magnetic resonance phase contrast imaging of the murine aortic arch
Open Access
- 8 November 2017
- journal article
- research article
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 12 (11) , e0187596
Abstract
Cardiovascular diseases remain the number one death cause worldwide. Preclinical 4D flow phase contrast magnetic resonance imaging can provide substantial insights in the analysis of aortic pathophysiologies in various animal models. These insights may allow a better understanding of pathophysiologies, therapy monitoring, and can possibly be translated to humans. This study provides a framework to acquire the velocity field within the aortic arch. It analyses important flow values at different locations within the aortic arch. Imaging parameters with high temporal and spatial resolution are provided, that still allow combining this time-consuming method with other necessary imaging-protocols. A new setup was established where a prospectively gated 4D phase contrast sequence is combined with a highly sensitive cryogenic coil on a preclinical magnetic resonance scanner. The sequence was redesigned to maintain a close to steady state condition of the longitudinal magnetization and hence to overcome steady state artifacts. Imaging parameters were optimized to provide high spatial and temporal resolution. Pathline visualizations were generated from the acquired velocity data in order to display complex flow patterns. Our setup allows data acquisition with at least two times the rate than that of previous publications based on Cartesian encoding, at an improved image quality. The “steady state” sequence reduces observed artifacts and provides uniform image intensity over the heart cycle. This made possible quantification of blood speed and wall shear stress (WSS) within the aorta and its branches. The highest velocities were observed in the ascending aorta with 137.5 ± 8 cm/s. Peak velocity values in the Brachiocephalic trunk were 57 ± 12 cm/s. Quantification showed that the peak flow occurs around 20 ms post R-wave in the ascending aorta. The highest mean axial wall shear stress was observed in the analysis plane between the left common carotid artery (LCCA) and the left subclavian artery. A stable image quality allows visualizing complex flow patterns by means of streamlines and for the first time, to the best of our knowledge, pathline visualizations from 4D flow MRI in mice. The described setup allows analyzing pathophysiologies in mouse models of cardiovascular diseases in the aorta and its branches with better image quality and higher spatial and temporal resolution than previous Cartesian publications. Pathlines provide an advanced analysis of complex flow patterns in the murine aorta. An imaging protocol is provided that offers the possibility to acquire the aortic arch at sufficiently high resolution in less than one hour. This allows the combination of the flow assessment with other multifunctional imaging protocols.Keywords
Funding Information
- Deutsche Forschungsgemeinschaft (EL 534/6-1)
This publication has 15 references indexed in Scilit:
- Velocity mapping of the aortic flow at 9.4 T in healthy mice and mice with induced heart failure using time-resolved three-dimensional phase-contrast MRI (4D PC MRI)Magnetic Resonance Materials in Physics, Biology and Medicine, 2014
- Fast retrospectively triggered local pulse-wave velocity measurements in mice with CMR-microscopy using a radial trajectoryJournal of Cardiovascular Magnetic Resonance, 2013
- 4D flow MRIJournal of Magnetic Resonance Imaging, 2012
- Functional and Morphological Cardiac Magnetic Resonance Imaging of Mice Using a Cryogenic Quadrature Radiofrequency CoilPLOS ONE, 2012
- Improved MR phase‐contrast velocimetry using a novel nine‐point balanced motion‐encoding scheme with increased robustness to eddy current effectsMagnetic Resonance in Medicine, 2012
- Four‐dimensional flow MRI using spiral acquisitionMagnetic Resonance in Medicine, 2011
- Three‐dimensional phase contrast angiography of the mouse aortic arch using spiral MRIMagnetic Resonance in Medicine, 2011
- In vivo measurement of local aortic pulse‐wave velocity in mice with MR microscopy at 17.6 teslaMagnetic Resonance in Medicine, 2009
- Quantitative 2D and 3D phase contrast MRI: Optimized analysis of blood flow and vessel wall parametersMagnetic Resonance in Medicine, 2008
- Assessment of motion gating strategies for mouse magnetic resonance at high magnetic fieldsJournal of Magnetic Resonance Imaging, 2004