Background: Statins are used to treat and prevent cardiovascular diseases (CVDs) by reducing the total serum cholesterol concentration. Unfortunately, dose-related side effects and sub-optimal response, attributed to non-adherence amongst others, were described. Therefore, a fast and sensitive liquid chromatography-high-resolution tandem mass spectrometry (LC-HRMS/MS) method for adherence testing and therapeutic drug monitoring of all currently marketed statins and their active metabolites in human blood plasma should be developed, validated and tested for applicability. Methods: Atorvastatin, fluvastatin, lovastatin, pitavastatin, pravastatin, rosuvastatin, and simvastatin, as well as ortho- and para-hydroxy-atorvastatin, lovastatin hydroxy acid and simvastatin hydroxy acid were included and several internal standards (IS) tested. Validation was performed according to the guideline of the European Medicines Agency including selectivity, carry-over, accuracy, precision, matrix effects, dilution integrity and analyte stability. Finally, applicability was tested using 14 patient samples submitted for regular toxicological analysis. Results: Due to an analytical interference of atorvastatin-d5, diazepam-d5 and pentobarbital-d5 were chosen as IS for positive and negative ionization mode, respectively. All statins and metabolites fulfilled the validation acceptance criteria except for fluvastatin, which could not be quantified reliably and reproducibly, most probably due to instability. Analyses of human plasma samples revealed concentrations of statins and metabolites below the reference plasma concentrations in the case of eight patients. However, nothing was known concerning patients’ adherence and time between intake and sampling. Conclusions: An LC-HRMS/MS method for identification and quantification of atorvastatin, lovastatin, pitavastatin, pravastatin, rosuvastatin, simvastatin and four active metabolites was successfully developed and applicability demonstrated.Keywords
This publication has 29 references indexed in Scilit:
- Simultaneous determination of sitagliptin and simvastatin in human plasma by LC‐MS/MS and its application to a human pharmacokinetic studyBiomedical Chromatography, 2012
- Simultaneous determination of simvastatin, lovastatin and niacin in human plasma by LC‐MS/MS and its application to a human pharmacokinetic studyBiomedical Chromatography, 2011
- Efficacy and safety of more intensive lowering of LDL cholesterol: a meta-analysis of data from 170 000 participants in 26 randomised trialsThe Lancet, 2010
- Liquid chromatography-tandem mass spectrometric assay for pravastatin and two isomeric metabolites in mouse plasma and tissue homogenatesJournal of Chromatography B, 2010
- Predictors of Nonadherence to Statins: A Systematic Review and Meta-AnalysisAnnals of Pharmacotherapy, 2010
- Identification of Genetic Variants Associated With Response to Statin TherapyArteriosclerosis, Thrombosis, and Vascular Biology, 2009
- Development and validation of a highly sensitive and robust LC‐ESI‐MS/MS method for simultaneous quantitation of simvastatin acid, amlodipine and valsartan in human plasma: application to a clinical pharmacokinetic studyBiomedical Chromatography, 2009
- Determination of lovastatin in human plasma by ultra-performance liquid chromatography–electrospray ionization tandem mass spectrometry and its application in a pharmacokinetic studyJournal of Pharmaceutical and Biomedical Analysis, 2008
- Chromatography–mass spectrometry methods for the quantitation of statins in biological samplesJournal of Pharmaceutical and Biomedical Analysis, 2007
- Simultaneous quantification of atorvastatin and active metabolites in human plasma by liquid chromatography–tandem mass spectrometry using rosuvastatin as internal standardBiomedical Chromatography, 2006