In lung stereotactic body radiotherapy (SBRT), variability of intrafractional target motion can negate the potential benefits of four‐dimensional (4D) treatment planning that aims to account for the dosimetric impacts of organ motion. This study used tumor motion data obtained from CyberKnife SBRT treatments to quantify the reproducibility of probability motion function (pmf) of 37 lung tumors. The reproducibility of pmf was analyzed with and without subtracting the intrafractional baseline drift from the original motion data. Statistics of intrafractional tumor motion including baseline drift, target motion amplitude and period, were also calculated. The target motion amplitude significantly correlates with variations (1 SD) of motion amplitude and baseline drift. Significant correlation between treatment time and variations (1 SD) of motion amplitude was observed in anterior‐posterior (AP) motion, but not in craniocaudal (CC) and left‐right (LR) motion. The magnitude of AP and LR baseline drifts significantly depend on the treatment time, while the CC baseline drift does not. The reproducibility of pmf as a function of time can be well described by a two‐exponential function with a fast and slow component. The reproducibility of pmf is over 60% for the CC motion and over 50% for the AP and LR motions when baseline variations were subtracted from the original motion data. It decreases to just over 30% for the CC motion and about 20% for the AP and LR motion, otherwise. 4D planning has obvious limitations due to variability of intrafractional target motion. To account for potential risks of overdosing critical organs, it is important to simulate the dosimetric impacts of intra‐ and interfractional baseline drift using population statistics obtained from SBRT treatments.PACS number: 87.55.‐xKeywords
Funding Information
- Hong Kong Adventist Hospital
This publication has 24 references indexed in Scilit:
- Quantification of the Variability of Diaphragm Motion and Implications for Treatment Margin ConstructionInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2012
- Treatment precision of image-guided liver SBRT using implanted fiducial markers depends on marker–tumour distancePhysics in Medicine & Biology, 2011
- Inter- and intrafractional localisation errors in cone-beam CT guided stereotactic radiation therapy of tumours in the liver and lungActa Oncologica, 2010
- Incorporating uncertainties in respiratory motion into 4D treatment plan optimizationMedical Physics, 2009
- Frameless Stereotactic Body Radiotherapy for Lung Cancer Using Four-Dimensional Cone Beam CT GuidanceInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2009
- Clinical Accuracy of the Respiratory Tumor Tracking System of the CyberKnife: Assessment by Analysis of Log FilesInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2009
- Reproducibility of Interfraction Lung Motion Probability Distribution Function Using Dynamic MRI: Statistical AnalysisInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2008
- An analysis of thoracic and abdominal tumour motion for stereotactic body radiotherapy patientsPhysics in Medicine & Biology, 2008
- Accuracy of tumor motion compensation algorithm from a robotic respiratory tracking system: A simulation studyMedical Physics, 2007
- Towards fluoroscopic respiratory gating for lung tumours without radiopaque markersPhysics in Medicine & Biology, 2005