Uncooled matrix IR detector based on optoacoustic cells and optoelectronic reading system
Authors:
- 1 March 2009
- journal article
- Published by Allerton Press in Optical Memory and Neural Networks
- Vol. 18 (1) , 25-28
Abstract
The matrix structure 200 × 200 of optoacoustic cells (OAC) for uncooled IR imager with optoelectronic reading system is fabricated and investigated at the first time. Cells 100 μm in diameter shaped on ZnSe window and filled by xenon. Photosensitive layer consisted of SiO2 film with adsorption range 8–14 μm. Flexible membrane 0.1 μm of thick consisted of SiO2 and Al films. Radiation temperature sensitivity and noise equivalent power with optics f/1 were 0.15 K/Hz1/2 and 10 nW/Hz1/2, respectively, and the thermal response time was below 30 ms.Keywords
This publication has 5 references indexed in Scilit:
- Uncooled infrared imaging device based on optimized optomechanical micro-cantilever arrayUltramicroscopy, 2008
- Polymeric Nanolayers as Actuators for Ultrasensitive Thermal BimorphsNano Letters, 2006
- Uncooled IR imager with 5-mK NEDT1997
- Two-dimensional micromechanical bimorph arrays for detection of thermal radiationApplied Physics Letters, 1997
- A Pneumatic Infra-Red DetectorReview of Scientific Instruments, 1947