We developed a universal, real-time uniform K-space sampling (Rt-UKSS) method for high-speed swept-source optical coherence tomography (SS-OCT). An external clock uniform in K-space was generated. The clock was synchronized with the zero-crossing time of an interferometric calibration signal and used as triggers for a high-speed data acquisition system in a point-by-point fashion, hence enabling uniform data sampling in K-space. Different from the numerical calibration algorithm commonly used in an SS-OCT system, the method reported here does not require over-sampling, thus greatly reducing the demand for digitization, data processing and storage speed. The Rt-UKSS method is adaptive and applicable to a generic SS-OCT system of a wide range of A-scan rates without special adjustment. We successfully implemented the Rt-UKSS method in an SS-OCT system based on a Fourier-domain mode-locked laser (FDML) of a 40-kHz scanning rate. Real-time imaging of biological tissues using such a system was demonstrated with a measured axial resolution of 9.3 μm and detection sensitivity greater than 120dB.Keywords
This publication has 10 references indexed in Scilit:
- Ultrahigh speed Spectral / Fourier domain OCT ophthalmic imaging at 70,000 to 312,500 axial scans per secondOptics Express, 2008
- K-space linear Fourier domain mode locked laser and applications for optical coherence tomographyOptics Express, 2008
- Fourier Domain Mode Locking (FDML): A new laser operating regime and applications for optical coherence tomographyOptics Express, 2006
- Three-dimensional and C-mode OCT imaging with a compact, frequency swept laser source at 1300 nmOptics Express, 2005
- Amplified, frequency swept lasers for frequency domain reflectometry and OCT imaging: design and scaling principlesOptics Express, 2005
- Improved signal-to-noise ratio in spectral-domain compared with time-domain optical coherence tomographyOptics Letters, 2003
- Sensitivity advantage of swept source and Fourier domain optical coherence tomographyOptics Express, 2003
- Performance of fourier domain vs time domain optical coherence tomographyOptics Express, 2003
- Optical coherence tomography using a frequency-tunable optical sourceOptics Letters, 1997