Detection of respiratory motion in fluoroscopic images for adaptive radiotherapy
Authors:
- T MoserTMT Moser
- J BiedererJBJ Biederer
- S NillSNS Nill
- G RemmertGRG Remmert
- R BendlRBR Bendl
- 21 May 2008
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 53 (12) , 3129-3145
Abstract
Respiratory motion limits the potential of modern high-precision radiotherapy techniques such as IMRT and particle therapy. Due to the uncertainty of tumour localization, the ability of achieving dose conformation often cannot be exploited sufficiently, especially in the case of lung tumours. Various methods have been proposed to track the position of tumours using external signals, e.g. with the help of a respiratory belt or by observing external markers. Retrospectively gated time-resolved x-ray computed tomography (4D CT) studies prior to therapy can be used to register the external signals with the tumour motion. However, during treatment the actual motion of internal structures may be different. Direct control of tissue motion by online imaging during treatment promises more precise information. On the other hand, it is more complex, since a larger amount of data must be processed in order to determine the motion. Three major questions arise from this issue. Firstly, can the motion that has occurred be precisely determined in the images? Secondly, how large must, respectively how small can, the observed region be chosen to get a reliable signal? Finally, is it possible to predict the proximate tumour location within sufficiently short acquisition times to make this information available for gating irradiation? Based on multiple studies on a porcine lung phantom, we have tried to examine these questions carefully. We found a basic characteristic of the breathing cycle in images using the image similarity method normalized mutual information. Moreover, we examined the performance of the calculations and proposed an image-based gating technique. In this paper, we present the results and validation performed with a real patient data set. This allows for the conclusion that it is possible to build up a gating system based on image data, solely, or (at least in avoidance of an exceeding exposure dose) to verify gates proposed by the various external systems.Keywords
This publication has 25 references indexed in Scilit:
- Robust fluoroscopic respiratory gating for lung cancer radiotherapy without implanted fiducial markersPhysics in Medicine & Biology, 2007
- Reproducible Simulation of Respiratory Motion in Porcine Lung ExplantsRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren, 2006
- Relation of external surface to internal tumor motion studied with cine CTMedical Physics, 2006
- Linac-integrated 4D cone beam CT: first experimental resultsPhysics in Medicine & Biology, 2006
- A strategy for automated multimodality image registration incorporating anatomical knowledge and imager characteristics2005
- Towards fluoroscopic respiratory gating for lung tumours without radiopaque markersPhysics in Medicine & Biology, 2005
- Residual motion of lung tumours in gated radiotherapy with external respiratory surrogatesPhysics in Medicine & Biology, 2005
- Compensation for respiratory motion by gated radiotherapy: an experimental studyPhysics in Medicine & Biology, 2005
- Correlation of lung tumor motion with external surrogate indicators of respirationInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2004
- Artificial Thorax for MR Imaging Studies in Porcine Heart-Lung PreparationsRadiology, 2003