Structural Reliability of Tall Buildings Under Wind Loads with Tuned Mass Damper Fluid Inerters
Open Access
Abstract
This study investigates the reliability of tall buildings subjected to dynamic across-wind loading, focusing on the Tuned Mass Damper Fluid Inerter (TMDFI). While existing literature emphasises the effectiveness of TMDFI in mitigating seismic hazards, research on its reliability regarding wind hazards remains limited. A wind-sensitive benchmark 76-storey building is modeled to compare the performance of the TMDFI against a traditional tuned mass damper (TMD) and an uncontrolled structure. A Monte Carlo Simulation (MCS) approach comprising 31,500 simulations is employed to assess reliability under uncertain damping ratios and varying turbulence intensities at reference wind speeds of 20 to 40 m/s. Key performance metrics, including peak acceleration and root mean squared (RMS) displacement responses, are derived through spectral analysis in the frequency domain. Results indicate that the TMDFI offers superior reliability, allowing an additional 6–7 m/s in reference velocity before reaching significant failure at the ISO limit state. Peak acceleration and RMS displacement are reduced by up to 64% to the uncontrolled structure. The TMDFI consistently outperforms both the TMD and uncontrolled configurations across all turbulent cases and wind velocities examined.Keywords
This publication has 42 references indexed in Scilit:
- Structural damping estimation from live monitoring of a tall modular buildingThe Structural Design of Tall and Special Buildings, 2023
- Review on vibration control in tall buildings: from the perspective of devices and applicationsInternational Journal of Dynamics and Control, 2020
- Experimental determination of structural damping of a full‐scale building with and without tuned liquid dampersStructural Control and Health Monitoring, 2020
- Vibration control of spar‐type floating offshore wind turbine towers using a tuned mass‐damper‐inerterStructural Control and Health Monitoring, 2019
- Optimal tuned mass-damper-inerter (TMDI) design for seismically excited MDOF structures with model uncertainties based on reliability criteriaStructural Control and Health Monitoring, 2017
- Improving performance of a super tall building using a new eddy-current tuned mass damperStructural Control and Health Monitoring, 2016
- Mitigation of wind response of a tall building using semi‐active tuned mass dampersThe Structural Design of Tall and Special Buildings, 2010
- Vertically distributed multiple tuned mass dampers in tall buildings: performance analysis and preliminary designThe Structural Design of Tall and Special Buildings, 2009
- Study on semi-active control of mega-sub controlled structure by MR damper subject to random wind loadsEarthquake Engineering and Engineering Vibration, 2008
- Effectiveness of tuned liquid dampers under wind excitationEngineering Structures, 1995