Validation of a Monte Carlo simulation for Microbeam Radiation Therapy on the Imaging and Medical Beamline at the Australian Synchrotron
Open Access
- 27 November 2019
- journal article
- research article
- Published by Springer Nature in Scientific Reports
- Vol. 9 (1) , 1-14
Abstract
Microbeam Radiation Therapy (MRT) is an emerging cancer treatment modality characterised by the use of high-intensity synchrotron-generated x-rays, spatially fractionated by a multi-slit collimator (MSC), to ablate target tumours. The implementation of an accurate treatment planning system, coupled with simulation tools that allow for independent verification of calculated dose distributions are required to ensure optimal treatment outcomes via reliable dose delivery. In this article we present data from the first Geant4 Monte Carlo radiation transport model of the Imaging and Medical Beamline at the Australian Synchrotron. We have developed the model for use as an independent verification tool for experiments in one of three MRT delivery rooms and therefore compare simulation results with equivalent experimental data. The normalised x-ray spectra produced by the Geant4 model and a previously validated analytical model, SPEC, showed very good agreement using wiggler magnetic field strengths of 2 and 3 T. However, the validity of absolute photon flux at the plane of the Phase Space File (PSF) for a fixed number of simulated electrons was unable to be established. This work shows a possible limitation of the G4SynchrotronRadiation process to model synchrotron radiation when using a variable magnetic field. To account for this limitation, experimentally derived normalisation factors for each wiggler field strength determined under reference conditions were implemented. Experimentally measured broadbeam and microbeam dose distributions within a Gammex RMI457 Solid Water® phantom were compared to simulated distributions generated by the Geant4 model. Simulated and measured broadbeam dose distributions agreed within 3% for all investigated configurations and measured depths. Agreement between the simulated and measured microbeam dose distributions agreed within 5% for all investigated configurations and measured depths.Keywords
Funding Information
- Department of Health | National Health and Medical Research Council (APP1093256)
- Australian Synchrotron proposals
This publication has 55 references indexed in Scilit:
- Volumetric modulated arc therapy: a review of current literature and clinical use in practiceBritish Journal of Radiology, 2011
- SHADOW3: a new version of the synchrotron X-ray optics modelling packageJournal of Synchrotron Radiation, 2011
- Radiochromic film dosimetry: Past, present, and futurePhysica Medica, 2011
- Tumor Cell Response to Synchrotron Microbeam Radiation Therapy Differs Markedly From Cells in Normal TissuesInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2010
- Monte Carlo simulation of RapidArc radiotherapy deliveryPhysics in Medicine & Biology, 2008
- Validation of a dose deposited by low-energy photons using GATE/GEANT4Physics in Medicine & Biology, 2008
- Tissue-sparing effect of x-ray microplanar beams particularly in the CNS: Is a bystander effect involved?Experimental Hematology, 2007
- Predictive factors for late normal tissue complications following radiotherapy for breast cancerBreast Cancer Research and Treatment, 2007
- Response of rat intracranial 9L gliosarcoma to microbeam radiation therapyNeuro-Oncology, 2002
- Response of rat intracranial 9L gliosarcoma to microbeam radiation therapyNeuro-Oncology, 2002