Fractional flow reserve‐guided paclitaxel‐coated balloon treatment for de novo coronary lesions
Authors:
- 1 October 2015
- journal article
- research article
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 88 (2) , 193-200
Abstract
Objectives: To assess the safety and efficacy of fractional flow reserve (FFR) guided paclitaxel‐coated balloon (PCB) treatment for de novo coronary artery lesions. Background: There is limited data on PCB treatment for de novo lesions especially of major epicardial coronary arteries.Methods: Sixty‐six patients with 67 de novo lesions who underwent successful plain old balloon angioplasty (POBA) were included. If POBA‐FFR was favorable (≥ 0.85), PCB was applied and if POBA‐FFR was P = 0.022). The baseline FFR of target lesions was 0.69 ± 0.16 in PCB and 0.60 ± 0.11 in stent group (P = 0.015), however, the FFR at 9 months was not different between groups (0.85 ± 0.08 in PCB vs. 0.85 ± 0.05 in stent group, P = 0.973). At 1 year, one myocardial infarction and one target lesion revascularization related to in‐stent restenosis were detected, both in the stent group.Conclusion: POBA‐FFR‐guided PCB treatment is safe and effective for de novo coronary lesions with good anatomical and physiological patency at mid‐term follow‐up.Keywords
This publication has 22 references indexed in Scilit:
- Prospective ‘real world’ registry for the use of the ‘PCB only’ strategy in small vessel de novo lesionsHeart, 2013
- Treatment of small coronary arteries with a paclitaxel-coated balloon catheter in the PEPCAD I study: are lesions clinically stable from 12 to 36 months?EuroIntervention, 2013
- Drug-coated balloons for treatment of coronary artery disease: updated recommendations from a consensus groupClinical Research in Cardiology, 2013
- Paclitaxel-eluting balloons, paclitaxel-eluting stents, and balloon angioplasty in patients with restenosis after implantation of a drug-eluting stent (ISAR-DESIRE 3): a randomised, open-label trialThe Lancet, 2013
- Paclitaxel-Coated Balloon Catheter Versus Paclitaxel-Coated Stent for the Treatment of Coronary In-Stent RestenosisCirculation, 2009
- One Step Forward and Two Steps Back With Drug-Eluting-StentsJACC: Cardiovascular Imaging, 2009
- Treatment of Coronary In-Stent Restenosis with a Paclitaxel-Coated Balloon CatheterNew England Journal of Medicine, 2006
- Pathology of Drug-Eluting Stents in HumansJACC, 2006
- Sirolimus-Eluting Stents versus Standard Stents in Patients with Stenosis in a Native Coronary ArteryNew England Journal of Medicine, 2003
- A Randomized Comparison of a Sirolimus-Eluting Stent with a Standard Stent for Coronary RevascularizationNew England Journal of Medicine, 2002