The Thermoluminescence Response of Ge-Doped Flat Fibers to Gamma Radiation
Authors:
- Siti Nurasiah Binti Mat NawiSNSiti Nurasiah Binti Mat Nawi
- Nor Fadira Binti WahibNWNor Fadira Binti Wahib
- Nurul Najua Binti ZulkepelyNZNurul Najua Binti Zulkepely
- Yusoff Bin Mohd AminYAYusoff Bin Mohd Amin
- Ung Ngie MinUMUng Ngie Min
- David Andrew BradleyDBDavid Andrew Bradley
- Roslan Bin Md NorRNRoslan Bin Md Nor
- Mohd Jamil MaahMMMohd Jamil Maah
Open Access
- 20 August 2015
- Vol. 15 (8) , 20557-20569
Abstract
Study has been undertaken of the thermoluminescence (TL) yield of various tailor-made flat cross-section 6 mol% Ge-doped silica fibers, differing only in respect of external dimensions. Key TL dosimetric characteristics have been investigated, including glow curves, dose response, sensitivity, fading and reproducibility. Using a 60Co source, the samples were irradiated to doses within the range 1 to 10 Gy. Prior to irradiation, the flat fibers were sectioned into 6 mm lengths, weighed, and annealed at 400 °C for 1 h. TL readout was by means of a Harshaw Model 3500 TLD reader, with TLD-100 chips (LiF:Mg, Ti) used as a reference dosimeter to allow the relative response of the fibers to be evaluated. The fibers have been found to provide highly linear dose response and excellent reproducibility over the range of doses investigated, demonstrating high potential as TL-mode detectors in radiation medicine applications. Mass for mass, the results show the greatest TL yield to be provided by fibers of the smallest cross-section, analysis indicating this to be due to minimal light loss in transport of the TL through the bulk of the silica medium.Keywords
Funding Information
- Ministry of Higher Education (MOHE), Malaysia (UM.C/HIR/MOHE/SC/33)
- Postgraduate Research Grant (PPP) University of Malaya (PG128-2014A)
This publication has 18 references indexed in Scilit:
- Enhancing the radiation dose detection sensitivity of optical fibresApplied Radiation and Isotopes, 2015
- Dosimetric characteristics of fabricated silica fibre for postal radiotherapy dose auditsJournal of Physics: Conference Series, 2014
- High sensitivity flat SiO2 fibres for medical dosimetryRadiation Physics and Chemistry, 2014
- Thermoluminescence characteristics of flat optical fiber in radiation dosimetry under different electron irradiation conditions2013
- Thermoluminescence Response of Germanium-Doped Optical Fibers to X-Ray IrradiationChinese Physics Letters, 2012
- Investigation of the use of Ge-doped optical fibre for in vitro IMRT prostate dosimetryNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2011
- Low-dose photon irradiation response of Ge and Al-doped SiO2 optical fibresApplied Radiation and Isotopes, 2011
- The thermoluminescence response of oxygen-doped optical fibres subjected to photon and electron irradiationsNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2010
- The thermoluminescence response of doped SiO2 optical fibres subjected to photon and electron irradiationsApplied Radiation and Isotopes, 2009
- The thermoluminescence response of Ge-doped optical fibre subjected to photon irradiationRadiation Physics and Chemistry, 2001