Haemodynamic determinants of the mitral valve closure sound: A finite element study
Authors:
- 1 November 2004
- journal article
- research article
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 42 (6) , 832-846
Abstract
Automatic acoustic classification and diagnosis of mitral valve disease remain outstanding biomedical problems. Although considerable attention has been given to the evolution of signal processing techniques, the mechanics of the first heart sound generation has been largely overlooked. In this study, the haemodynamic determinants of the first heart sound were examined in a computational model. Specifically, the relationship of the transvalvular pressure and its maximum derivative to the time-frequency content of the acoustic pressure was examined. To model the transient vibrations of the mitral valve apparatus bathed in a blood medium, a dynamic, non-linear, fluid-coupled finite element model of the mitral valve leaflets and chordae tendinae was constructed. It was found that the root mean squared (RMS) acoustic pressure varied linearly (r2=0.99) from 0.010 to 0.259 mm Hg, following an increase in maximum dP/dt from 415 to 12470 mm Hg s−1. Over that same range, peak frequency varied non-linearly from 59.6 to 88.1 Hz. An increase in left-ventricular pressure at coaptation from 22.5 to 58.5 mm Hg resulted in a linear (r2=0.91) rise in RMS acoustic pressure from 0.017 to 1.41 mm Hg. This rise in transmitral pressure was accompanied by a non-linear rise in peak frequency from 63.5 to 74.1 Hz. The relationship between the transvalvular pressure and its derivative and the time-frequency content of the first heart sound has been examined comprehensively in a computational model for the first time. Results suggest that classification schemes should embed both of these variables for more accurate classification.Keywords
This publication has 45 references indexed in Scilit:
- An adaptive optimal-kernel time-frequency representationIEEE Transactions on Signal Processing, 1995
- Time-frequency analysis of the first heart soundIEEE Engineering in Medicine and Biology Magazine, 1995
- Digital Signal Processing of the Phonocardiogram: Review of the Most Recent AdvancementsCritical Reviews in Biomedical Engineering, 1995
- The spectrum of mitral regurgitation in idiopathic mitral valve prolapse: a Color Doppler studyThe International Journal of Cardiovascular Imaging, 1990
- Cardiac sound and ultrasound echocardiographic and phonocardiographic correlations—Part ICurrent Problems in Cardiology, 1981
- Analysis of mitral and aortic valve vibrations and their role in the production of the first and second heart soundsPhysics in Medicine & Biology, 1980
- One-dimensional model of diastolic semilunar valve vibrations productive of heart soundsJournal of Biomechanics, 1979
- Intracardiac phonocardiography: intracardiac sound and pressure in man.Circulation, 1978
- The first heart sound.Circulation, 1978
- A study of the dynamic relations between the mitral valve echogram and phasic mitral flow.Circulation, 1975