Variation in Carotid Artery Stenosis Measurements Among Facilities Seeking Carotid Stenting Facility Accreditation
- 1 June 2023
- journal article
- research article
- Published by Wolters Kluwer Health in Stroke
- Vol. 54 (6) , 1578-1586
Abstract
Background: Based on the inclusion criteria of clinical trials, the degree of cervical carotid artery stenosis is often used as an indication for stent placement in the setting of extracranial carotid atherosclerotic disease. However, the rigor and consistency with which stenosis is measured outside of clinical trials are unclear. In an agreement study using a cross-sectional sample, we compared the percent stenosis as measured by real-world physician operators to that measured by independent expert reviewers. Methods: As part of the carotid stenting facility accreditation review, images were obtained from 68 cases of patients who underwent carotid stent placement. Data collected included demographics, stroke severity measures, and the documented degree of stenosis, termed operator-reported stenosis (ORS), by 34 operators from 14 clinical sites. The ORS was compared with reviewer-measured stenosis (RMS) as assessed by 5 clinicians experienced in treating carotid artery disease. Results: The median ORS was 90.0% (interquartile range, 80.0%–90.0%) versus a median RMS of 61.1% (interquartile range, 49.8%–73.6%), with a median difference of 21.8% (interquartile range, 13.7%–34.4%), P P =0.406). The median difference between ORS and RMS for facilities granted initial accreditation was smaller compared with facilities whose accreditation was delayed (17.9% versus 25.5%, P =0.035). The intraclass correlation between ORS and RMS was 0.16, indicating poor agreement. If RMS measurements were used, 72% of symptomatic patients and 10% of asymptomatic patients in the population examined would meet the Centers for Medicare and Medicaid Services criteria for stent placement. Conclusions: Real-world operators tend to overestimate carotid artery stenosis compared with external expert reviewers. Measurements from facilities granted initial accreditation were closer to expert measurements than those from facilities whose accreditation was delayed. Since decisions regarding carotid revascularization are often based on percent stenosis, such measuring discrepancies likely lead to increased procedural utilization.Keywords
This publication has 19 references indexed in Scilit:
- Guidelines for Reporting Reliability and Agreement Studies (GRRAS) were proposedJournal of Clinical Epidemiology, 2011
- Stenting versus Endarterectomy for Treatment of Carotid-Artery StenosisNew England Journal of Medicine, 2010
- Internal Carotid Artery Stenosis: Accuracy of Subjective Visual Impression for Evaluation with Digital Subtraction Angiography and Contrast-enhanced MR AngiographyRadiology, 2007
- The inaccuracy of simple visual interpretation for measurement of carotid stenosis by arteriographyJournal of Vascular Surgery, 2005
- Benefit of Carotid Endarterectomy in Patients with Symptomatic Moderate or Severe StenosisNew England Journal of Medicine, 1998
- Variability in Measurement of Extracranial Internal Carotid Artery Stenosis as Displayed by Both Digital Subtraction and Magnetic Resonance AngiographyStroke, 1996
- Endarterectomy for Asymptomatic Carotid Artery StenosisJAMA, 1995
- Carotid Stenosis IndexStroke, 1995
- Measuring carotid stenosis. Time for a reappraisal.Stroke, 1993
- Beneficial Effect of Carotid Endarterectomy in Symptomatic Patients with High-Grade Carotid StenosisNew England Journal of Medicine, 1991