3 T MR Assessment of Pituitary Microadenomas
Authors:
- 1 December 2004
- journal article
- Published by SAGE Publications in Rivista di Neuroradiologia
- Vol. 17 (6) , 890-895
Abstract
Demonstration and accurate localisation of pituitary microadenomas in the adenohypophysis are essential to institute appropriate medical management and aid surgical planning, especially when an endoscopic procedure is envisaged. Given the features of pituitary microadenomas, ideally, high spatial and temporal resolution is required for neuroradiological investigation. There is a consensus in the literature that MR scanning is the method of choice for pituitary imaging and dynamic studies offer greater sensitivity in identifying pituitary microadenomas. However, the spatial resolution and limited number of slices acquired constitute major drawbacks using 1.5 T MR devices. A 3 Tesla Signa Excite MR system (GE Medical Systems) was recently installed in the Neuroradiology Unit of Bellaria Hospital, Bologna. The new device was tested specifically for the study of pituitary microadenomas using an FSE dynamic sequence allowing the acquisition of nine slices (slice thickness 2.5 mm) over the pituitary gland with high spatial resolution in a few seconds. This sequence, repeated six times after gadolinium administration through an injector, displays the gradual enhancement of the adenohypophysis and any microadenomas present in the gland. As the microadenoma uptake of gadolinium is lower than the adenohypophysis uptake, the possible microadenoma presence becomes appreciable only in some of the six sequences as a negative image with respect to the normal parenchyma. Pituitary microadenomas undetected in previous scans using a 1.5 T system were disclosed by this imaging technique with highly accurate morphological localisation.Keywords
This publication has 14 references indexed in Scilit:
- High field body MR imaging: Preliminary experiencesClinical Imaging, 2004
- MR imaging at high magnetic fieldsEuropean Journal of Radiology, 2003
- Dynamic spin‐echo imaging: Theoretical assessment and implementationJournal of Magnetic Resonance Imaging, 1994
- Varied microcirculation of pituitary adenomas at rapid, dynamic, contrast-enhanced MR imaging.Radiology, 1993
- Normal and abnormal pituitary glands: gadopentetate dimeglumine-enhanced MR imaging.Radiology, 1991
- Pituitary adenomas and normal pituitary tissue: enhancement patterns on gadopentetate-enhanced MR imaging.Radiology, 1990
- Pituitary adenomas: high-resolution MR imaging at 1.5 T.Radiology, 1986
- Dynamic computed tomography of the pituitary gland: the "tuft sign".Radiology, 1983
- Computed tomographic study of hormone-secreting microadenomas.Radiology, 1983
- Mapping of metabolites in whole animals by 31P NMR using surface coilsNature, 1980