4D Micro-Computed X-ray Tomography as a Tool to Determine Critical Process and Product Information of Spin Freeze-Dried Unit Doses
Open Access
- 7 May 2020
- journal article
- research article
- Published by MDPI AG in Pharmaceutics
- Vol. 12 (5) , 430
Abstract
Maintaining chemical and physical stability of the product during freeze-drying is important but challenging. In addition, freeze-drying is typically associated with long process times. Therefore, mechanistic models have been developed to maximize drying efficiency without altering the chemical or physical stability of the product. Dried product mass transfer resistance ( ) is a critical input for these mechanistic models. Currently available techniques to determine only provide an estimation of the mean and do not allow measuring and determining essential local (i.e., intra-vial) differences. In this study, we present an analytical method, based on four-dimensional micro-computed tomography (4D- CT), which enables the possibility to determine intra-vial differences. Subsequently, these obtained values are used in a mechanistic model to predict the drying time distribution of a spin-frozen vial. Finally, this predicted primary drying time distribution is experimentally verified via thermal imaging during drying. It was further found during this study that 4D- CT uniquely allows measuring and determining other essential freeze-drying process parameters such as the moving direction(s) of the sublimation front and frozen product layer thickness, which allows gaining accurate process knowledge. To conclude, the study reveals that the variation in the end of primary drying time of a single vial could be predicted accurately using 4D- CT as similar results were found during the verification using thermal imaging.
Keywords
Funding Information
- Fonds Wetenschappelijk Onderzoek (1S23417N)
- Bijzonder Onderzoeksfonds (BOF.EXP.2017.000007)
This publication has 31 references indexed in Scilit:
- Recent micro-CT scanner developments at UGCTNuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, 2014
- Quantitative X-ray tomographyInternational Materials Reviews, 2014
- Quality by design: optimization of a freeze-drying cycle via design space in case of heterogeneous drying behavior and influence of the freezing protocolPharmaceutical Development and Technology, 2012
- The freezing step in lyophilization: Physico-chemical fundamentals, freezing methods and consequences on process performance and quality attributes of biopharmaceuticalsEuropean Journal of Pharmaceutics and Biopharmaceutics, 2011
- Product mass transfer resistance directly determined during freeze-drying cycle runs using tunable diode laser absorption spectroscopy (TDLAS) and pore diffusion modelPharmaceutical Development and Technology, 2010
- Development of simplified models for the freeze-drying process and investigation of the optimal operating conditionsChemical Engineering Research and Design, 2008
- Modeling of freezing step during freeze‐drying of drugs in vialsAIChE Journal, 2007
- Rapid determination of dry layer mass transfer resistance for various pharmaceutical formulations during primary drying using product temperature profilesInternational Journal of Pharmaceutics, 2006
- Review of the vapour pressures of ice and supercooled water for atmospheric applicationsQuarterly Journal of the Royal Meteorological Society, 2005
- Determination of mass transfer coefficients during freeze drying using modeling and parameter estimation techniquesInternational Journal of Pharmaceutics, 1995