Objective. We tested the hypothesis that NO contamination of hospital compressed air also improves PaO2 in patients with acute lung injury (ALI) and following lung transplant (LTx). Design. Prospective clinical study. Setting. Cardiothoracic intensive care unit. Patients. Subjects following cardiac surgery (CABG, n=7); with ALI (n=7), and following LTx (n=5). Interventions. Four sequential 15-min steps at a constant FiO2 were used: hospital compressed air-O2 (H1), N2-O2 (Aff1), repeat compressed air-O2 (H2), and repeat N2-O2 (Aff2). Measurements and results. NO levels were measured from the endotracheal tube. Cardiorespiratory values included PaO2 were measured at the end of each step. FiO2 was 0.46±0.05, 0.53±0.15, and 0.47±0.06 (mean±SD) for three groups, respectively. Inhaled NO levels during H1 varied among subjects (30–550 ppb, 27–300 ppb, and 5–220 ppb, respectively). Exhaled NO levels were not detected in 4/7 of CABG (0–300 ppb), 3/6 of ALI (0–140 ppb), and 3/5 of LTx (0–59 ppb) patients during H1, whereas during Aff1 all but one patient in ALI and three CABG patients had measurable exhaled NO levels (P2 occurred for all groups from H1 to Aff1 and H2 to Aff2 (132–99 Torr and 128–120 Torr, P 2 from H1 to Aff1. Conclusions. Low-level NO contamination improves PaO2 in patients with ALI and following LTx.