Grain size measurement from two-dimensional micro-X-ray diffraction: Laboratory application of a radial integration technique
- 14 August 2015
- journal article
- Published by Mineralogical Society of America in American Mineralogist: Journal of Earth and Planetary Materials
- Vol. 100 (8-9) , 1899-1911
Abstract
Two-dimensional X-ray diffraction data contain information about not only the type of mineral phases present in an assemblage, but also the textural or grain size relationships between minerals in a sample. For minerals within a certain grain size range, ~0.1 to 100 μm, the appearance and characteristics of a Debye ring can reveal the mean grain size of a sample. In this contribution, using mineral and rock samples of known grain size ranges, we investigate the applicability of calculating the grain size of a material using a two-dimensional X-ray diffraction crystallite size analysis method for micrometer-sized materials. A radial integration technique was used to derive the number of grains contributing to produce diffraction spots in the Debye ring. Monomineralic pyroxene and magnetite samples of known grain size ranges were analyzed, and the calculated grain size was observed to broadly correlate with the sample size except at the upper and lower extremes. To evaluate the technique on broader geological materials, polymineralic basalt samples with known grain size ranges were analyzed, and the calculated grain sizes did not correlate with the size of the rock fragments, but did correlate closely with the size of the individual mineral grains. Using a Bruker D8 Discover X-ray diffractometer with a 300 μm nominal incident beam diameter, the effectiveness of the applied method appeared limited to the grain size range of ~15–63 μm for monomineralic samples. The method is further limited by several complicating factors and assumptions, including the requirement for the crystallite size to correlate with the sample grain size. The effective range of this method will vary with different instrumental and experimental conditions. When applying this method to calculate the grain size of geological materials, the calculated result should be interpreted as a minimum estimate of the grain size.Keywords
This publication has 25 references indexed in Scilit:
- A temperature-controlled sample stage for in situ micro-X-ray diffraction: Application to Mars analog mirabilite-bearing perennial cold spring precipitate mineralogyAmerican Mineralogist: Journal of Earth and Planetary Materials, 2014
- Characterization and Calibration of the CheMin Mineralogical Instrument on Mars Science LaboratorySpace Science Reviews, 2012
- Crystal chemistry of the magnetite-ulvospinel seriesAmerican Mineralogist: Journal of Earth and Planetary Materials, 2009
- Ultraviolet spectral reflectance properties of common planetary mineralsIcarus, 2008
- Size–strain line-broadening analysis of the ceria round-robin sampleJournal of Applied Crystallography, 2004
- Site preference of rare earth elements in fluorapatite; binary (LREE+HREE)-substituted crystalsAmerican Mineralogist: Journal of Earth and Planetary Materials, 1997
- On the Crystallographic and Magnetic Structures of Nearly Stoichiometric Iron MonoxideJournal of Solid State Chemistry, 1996
- The structure of bytownite quenched from 1723 KActa Crystallographica Section B: Structural Science, Crystal Engineering and Materials, 1979
- Debye-scherrer investigations of experimentally shocked silicatesEarth, Moon, and Planets, 1973
- A study of cold-worked aluminium by an X-ray microbeam technique. I. Measurement of particle volume and misorientationsActa Crystallographica, 1952