Comparison of IMRT and VMAT plans with different energy levels using Monte-Carlo algorithm for prostate cancer
- 8 February 2014
- journal article
- research article
- Published by Springer Nature in Japanese Journal of Radiology
- Vol. 32 (4) , 224-232
Abstract
To make dosimetric comparisons of volumetric-modulated arc therapy (VMAT) and 7-field intensity-modulated radiotherapy (IMRT) with dynamic MLCs using the Monaco treatment planning system with Monte Carlo algorithm. Single-arc VMAT and 7-field IMRT treatment plans were compared for 12 intermediate risk prostate cancer patients treated with prostate and seminal vesicle radiotherapy. For all patients, the prescribed dose was 78 Gy delivered in 39 fractions. The dosimetric data of IMRT and VMAT plans with 6, 10 and 15 MV energies were compared. The comparison was made for target volume, organs at risk (OAR) doses, and for monitor units (MU). The normal tissue surrounding the target were lower in VMAT plans compared to IMRT plans. VMAT plans achieved lower doses to all OARs for nearly all dosimetric endpoints. VMAT plans achieved 9.4, 9.0 and 7.0 % relative decrease in MUs required for RT delivery, for 6, 10 and 15 MV energy levels, respectively. The target volume and OAR dosimetric values did not differ significantly between 6, 10 and 15 MV photon energies. VMAT plans were found to be dosimetrically equivalent to IMRT plans for prostate cancer patients, with better rectum and bladder sparing and fewer MUs required.Keywords
This publication has 35 references indexed in Scilit:
- Comparison of total MU and segment areas in VMAT and step-and-shoot IMRT plansRadiological Physics and Technology, 2012
- The effect of 6 and 15 MV on intensity-modulated radiation therapy prostate cancer treatment: plan evaluation, tumour control probability and normal tissue complication probability analysis, and the theoretical risk of secondary induced malignanciesBritish Journal of Radiology, 2012
- RapidArc radiotherapy planning for prostate cancer: Single-arc and double-arc techniques vs. intensity-modulated radiotherapyMedical Dosimetry, 2012
- Treatment and Dosimetric Advantages Between VMAT, IMRT, and Helical TomoTherapy in Prostate CancerMedical Dosimetry, 2011
- Comparison of Prostate IMRT and VMAT Biologically Optimised Treatment PlansMedical Dosimetry, 2011
- Volumetric Modulated Arc Therapy: Planning and Evaluation for Prostate Cancer CasesInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2010
- Volumetric modulated arc therapy: IMRT in a single gantry arcMedical Physics, 2007
- Dose-Response in Radiotherapy for Localized Prostate Cancer: Results of the Dutch Multicenter Randomized Phase III Trial Comparing 68 Gy of Radiotherapy With 78 GyJournal of Clinical Oncology, 2006
- Dosimetric issues in radiation protection of radiotherapy patientsRadiation Protection Dosimetry, 2006
- Radiation-induced second cancers: the impact of 3D-CRT and IMRTInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2003