Possible Biliary Disease: Diagnostic Performance of High-Spatial-Resolution Isotropic 3D T2-weighted MRCP
Authors:
- Hero K. HussainHHHero K. Hussain
- William J. WeadockWWWilliam J. Weadock
- Erik J. WamstekerEWErik J. Wamsteker
- Timothy D. JohnsonTJTimothy D. Johnson
- Asra S. KhanAKAsra S. Khan
- Anthony R. D'AMicoADAnthony R. D'AMico
- Matthew K. FordMFMatthew K. Ford
- Sirisha R. NandalurSNSirisha R. Nandalur
- Thomas L. ChenevertTCThomas L. Chenevert
- 1 December 2008
- journal article
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 249 (3) , 883-890
Abstract
To retrospectively assess the diagnostic performance of magnetic resonance cholangiopancreatography (MRCP) performed by using a high-spatial-resolution isotropic three-dimensional (3D) fast-recovery fast spin-echo (FSE) sequence with parallel imaging for the evaluation of possible biliary disease. This HIPAA-compliant study was approved by the institutional review board; informed consent was waived. Ninety-five patients (58 female, 37 male; mean age, 51 years; range, 15-91 years) underwent MRCP by using the respiratory-triggered isotropic 3D fast-recovery FSE sequence and endoscopic or percutaneous direct visualization between March 2003 and June 2007. Two independent readers evaluated the MRCP images for strictures, dilatation, and intraductal filling defects. Sensitivity, specificity, and interobserver agreement (kappa statistics) were determined. The respective sensitivity and specificity for strictures, dilatation, and intraductal filling defects (all choledocholithiasis) were 86% (40 of 47) and 94% (45 of 48), 98% (57 of 58) and 100% (37 of 37), and 68% (19 of 28) and 97% (65 of 67) for reader 1 and 88% (41 of 47) and 94% (45 of 48), 96% (56 of 58) and 100% (37 of 37), and 75% (21 of 28) and 99% (66 of 67) for reader 2. The sensitivity for stones larger than 3 mm was 94% (15 of 16) for reader 1 and 100% (16 of 16) for reader 2, whereas the sensitivity for stones 3 mm or smaller was 33% (four of 12) for reader 1 and 42% (five of 12) for reader 2. Agreement between readers was good to excellent, with kappa values of 0.76, 0.85, and 0.98 for strictures, dilatation, and choledocholithiasis, respectively. MRCP by using the respiratory-triggered isotropic 3D fast-recovery FSE sequence with parallel imaging demonstrates excellent diagnostic capabilities for possible biliary disease, although it is limited for stones 3 mm or smaller in size.Keywords
This publication has 20 references indexed in Scilit:
- The relative roles of magnetic resonance cholangiopancreatography (MRCP) and endoscopic ultrasound in diagnosis of malignant common bile duct strictures: a critically appraised topicAbdominal Radiology, 2007
- The relative roles of magnetic resonance cholangiopancreatography (MRCP) and endoscopic ultrasound in diagnosis of common bile duct calculi: a critically appraised topicAbdominal Radiology, 2007
- Isotropic 3D T2-Weighted MR Cholangiopancreatography with Parallel Imaging: Feasibility StudyAmerican Journal of Roentgenology, 2006
- Respiratory‐triggered MRCP applying parallel acquisition techniquesJournal of Magnetic Resonance Imaging, 2006
- Value of Adding T1-Weighted Image to MR Cholangiopancreatography for Detecting Intrahepatic Biliary StonesAmerican Journal of Roentgenology, 2006
- Parallel acquisition techniques for accelerated volumetric interpolated breath‐hold examination magnetic resonance imaging of the upper abdomen: Assessment of image quality and lesion conspicuityJournal of Magnetic Resonance Imaging, 2005
- Magnetic Resonance CholangiopancreatographyAnnals of Internal Medicine, 2003
- Detection of Choledocholithiasis with MR Cholangiography: Comparison of Three-dimensional Fast Spin-Echo and Single- and Multisection Half-Fourier Rapid Acquisition with Relaxation Enhancement SequencesRadiology, 2000
- MR cholangiopancreatography: prospective comparison of a breath-hold 2D projection technique with diagnostic ERCPEuropean Radiology, 1999
- MR cholangiopancreatography: efficacy of three-dimensional turbo spin-echo technique.American Journal of Roentgenology, 1995