Optimization of reverse osmosis treatment process to reuse the distillery wastewater using Taguchi design
Open Access
- 29 January 2016
- journal article
- research article
- Published by Elsevier in Desalination and Water Treatment
- Vol. 57 (51) , 24222-24230
Abstract
In this study, the reverse osmosis (RO) treatment of distillery wastewater was studied using various operating conditions including pH, temperature, transmembrane pressure, and feed flow rate. Taguchi method was used to design the experiments and optimize the RO treatment process for the maximum permeate flux and removal of salinity and COD. L9 (34) orthogonal array for experimental design and the larger-the-better response category was applied to find optimum parameters. The optimum conditions were found to be as pH (6), temperature (45°C), transmembrane pressure (10 bar), and flow rate (300 l/h). Under these conditions, 80 l/hm2 permeate flux was achieved with 91% of salinity removal and 85% of COD removal. The obtained results revealed that RO treatment technique was an effective treatment technology for the reuse of distilleries wastewater.Keywords
This publication has 23 references indexed in Scilit:
- Reducing specific energy consumption in Reverse Osmosis (RO) water desalination: An analysis from first principlesDesalination, 2011
- Advanced treatment of pulp and paper mill wastewater by nanofiltration process: Effects of operating conditions on membrane foulingSeparation and Purification Technology, 2011
- A review of membrane processes and renewable energies for desalinationDesalination, 2009
- Phosphate limitation in reverse osmosis: An option to control biofouling?Desalination and Water Treatment, 2009
- Chemical and physical aspects of cleaning of organic-fouled reverse osmosis membranesJournal of Membrane Science, 2006
- Fouling autopsy of hollow-fibre MF membranes in wastewater reclamationDesalination, 2006
- Colloidal fouling of RO membranes: an overview of key issues and efforts to develop improved prediction techniquesDesalination, 2005
- Tools for fouling diagnosis of NF and RO membranes and assessment of the fouling potential of feed waterDesalination, 2003
- Four years field experience with fouling resistant reverse osmosis membranesDesalination, 2000
- A simple equation for description of solute release II. Fickian and anomalous release from swellable devicesJournal of Controlled Release, 1987