Multivariate determination of glucose concentrations from optimally filtered frequency-warped NIR spectra of human blood serum
Authors:
- 1 February 1996
- journal article
- research article
- Published by IOP Publishing in Physiological Measurement
- Vol. 17 (1) , 1-20
Abstract
Glucose concentrations over the 39-160 mg dl-1 range have been determined from 357 NIR (near-infrared) spectra of human blood serum in the spectral region from 6766 cm-1 to 4003 cm-1. A frequency-warping procedure was applied to the NIR data to compress 511 spectral components into 102 in the 6766-4003 cm-1 spectral region. Before the data compression process was carried out, the NIR spectrum of deionized water was subtracted from each of the blood serum spectra to remove the intrinsic high background absorption due to the water. PLS (partial least-squares) regression was coupled with time-domain digital Butterworth bandpass filtering in an optimization procedure. The optimization procedure was carried out over a range of centre frequencies and bandwidths for first- (two-pole), second- (four-pole) and third- (six-pole) order bandpass filters, and over a range of PLS factors. The optimal PLS model and filter parameters were determined from a sequence of three-dimensional performance response maps for different numbers of PLS factors and filter orders. As a basis for comparison, the same optimization process was carried out for a Gaussian filter design approach (i.e., Fourier filtering). Using the optimally filtered frequency-warped NIR spectral data, an SEP (standard error of prediction) of 13.2 mg dl-1 was achieved fro the test (monitoring) data using 14 PLS factors and a simple first-order (two-pole) digital Butterworth bandpass filter.Keywords
This publication has 9 references indexed in Scilit:
- Raman Spectroscopy Studies of Metabolic Concentrations in Aqueous Solutions and Aqueous Humor SpecimensApplied Spectroscopy, 1995
- HypoglycemiaDiabetes Care, 1994
- Strategies for coupling digital filtering with partial least-squares regression: Application to the determination of glucose in plasma by Fourier-transform near-infrared spectroscopyAnalytical Chemistry, 1993
- Multivariate Determination of Glucose in Whole Blood Using Partial Least-Squares and Artificial Neural Networks Based on Mid-Infrared SpectroscopyApplied Spectroscopy, 1993
- Noninvasive Glucose Monitoring in Diabetic Patients: A Preliminary EvaluationClinical Chemistry, 1992
- Determination of physiological levels of glucose in an aqueous matrix with digitally filtered Fourier transform near-infrared spectraAnalytical Chemistry, 1990
- New Approach to Technical and Clinical Evaluation of Devices for Self-Monitoring of Blood GlucoseDiabetes Care, 1988
- Partial least-squares regression: a tutorialAnalytica Chimica Acta, 1986
- Potential Pitfalls in the Use of Glucoscan and Glucoscan II Meters for Self-Monitoring of Blood GlucoseDiabetes Care, 1984