Technical performance of the Luxel Al2O3:C optically stimulated luminescence dosemeter element at radiation oncology and nuclear accident dose levels
Authors:
- Steven D. MillerSMSteven D. Miller
- Mark K. MurphyMMMark K. Murphy
- 12 December 2006
- journal article
- research article
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 123 (4) , 435-442
Abstract
The dose ranges typical for radiation oncology and nuclear accident dosimetry are on the order of 2–70 Gy and 0.1–5 Gy, respectively. In terms of solid-state passive dosimetry, thermoluminescent (TL) materials historically have been used extensively for these two applications, with silver-halide, leuco-dye and BaFBr:Eu-based films being used on a more limited basis than TL for radiation oncology. This present work provides results on the performance of a film based on an aluminum oxide, Al2O3:C, for these dosimetry applications, using the optically stimulated luminescence (OSL) readout method. There have been few investigations of Al2O3:C performance at radiation oncology and nuclear accident dose levels, and these have included minimal dosimetric and environmental effects information. Based on investigations already published, the authors of this present study determined that overall improvements over film and TLDs for this Al2O3:C OSL technology at radiation oncology and nuclear accident dose levels may include (1) a more tissue-equivalent response to photons compared to X-ray film, (2) higher sensitivity, (3) ability to reread dosemeters and (4) diagnostic capability using small-area imaging. The results of the present investigation indicate that additional favourable performance characteristics for the Al2O3:C dosemeter are a wide dynamic range (0.001–100 Gy), a response insensitive to temperature and moisture over a wide range, negligible dose rate dependence, and minimal change in post-irradiation response. As a radiation detection medium, this OSL phosphor offers an assortment of dosimetry properties that will permit it to compete with current radiation detection technologies such as silver-halide, leuco-dye and photostimulable-phosphor-based films, as well as TLDs.Keywords
This publication has 20 references indexed in Scilit:
- High-precision dosimetry for radiotherapy using the optically stimulated luminescence technique and thin Al2O3:C dosimetersPhysics in Medicine & Biology, 2005
- Recent advances in dosimetry using the optically stimulated luminescence of Al2O3:CRadiation Protection Dosimetry, 2004
- Topics under Debate - On the advantages and disadvantages of optically stimulated luminescence dosimetry and thermoluminescence dosimetryRadiation Protection Dosimetry, 2003
- Characterisation of Al2O3 for Use in Thermally and Optically Stimulated Luminescence DosimetryRadiation Protection Dosimetry, 1999
- Influence of Point Defects on the Thermoluminescence of a-Al2O3: Application to DosimetryRadiation Protection Dosimetry, 1999
- A Radiation Dosimetry Method Using Pulsed Optically Stimulated LuminescenceRadiation Protection Dosimetry, 1999
- A Thin-Layer Al2O3:C Beta TL DetectorRadiation Protection Dosimetry, 1996
- Pulsed Optically Stimulated Luminescence Dosimetry Using Alpha-Al2O3:CRadiation Protection Dosimetry, 1996
- Temperature, humidity and time. Combined effects on radiochromic film dosimetersRadiation Physics and Chemistry, 1996
- Time-resolved optically stimulated luminescence from α-Al2O3:CRadiation Measurements, 1995