Clipless Cholecystectomy: Which Sealer Should be Used?
- 19 November 2010
- journal article
- research article
- Published by Wiley in World Journal of Surgery
- Vol. 35 (4) , 817-823
Abstract
Background: The use of the Harmonic Scalpel (HS) for cystic duct ligation began with little data about its efficacy or safety. On the other hand, there is not any literature available about the use of PlasmaKinetic Sealer (PK) for closing the cystic duct in laparoscopic cholecystectomy (LC). Therefore, this study was designed to compare the efficacy and safety of HS and PK for achieving safe closure of the cystic ducts after LC.Methods: Ninety patients with symptomatic gallstone disease were enrolled in this prospective case control study. The patients were operated with laparoscopic technic and divided into three groups (n = 30) randomly. After the dissection of Calot’s triangle, proximal cystic ducts on common bile ducts were sealed with single surgical clips (SC) in all groups, and in the first group, distal of the cystic ducts also was sealed with single SC and the gallbladders were removed with SC. In the second and third groups, distal of the cystic ducts were sealed with HS and PK, respectively. The gallbladders were removed as sealed cystic ducts with HS and PK. Then, gallbladders were connected to a transducer set and increasing pressure with saline was applied. The bursting pressures of gallbladders were measured and differences between the groups were calculated by using Student’s t test. The value of P < 0.05 was accepted as significant.Results: In this study, the mean cystic duct bursting pressures were 332.46 ± 4.62 mmHg with SC, 326.56 ± 4.53 mmHg with PK, and 343.06 ± 4.28 mmHg with HS. Differences of the mean cystic duct bursting pressures between the groups were indicated the superior results of HS.Conclusions: The results of this study indicated that HS is more effective than PK and as safe and effective as SC for cystic duct closure.Keywords
This publication has 30 references indexed in Scilit:
- Sphincter of Oddi: Function, dysfunction, and its managementJournal of Gastroenterology and Hepatology, 2009
- Technical Section: Technical notes & tipsThe Annals of The Royal College of Surgeons of England, 2008
- Clipless Laparoscopic Cholecystectomy by Ultrasonic DissectionJournal of Laparoendoscopic & Advanced Surgical Techniques, 2008
- PlasmaKinetic Bipolar Vessel Sealing: Burst Pressures and Thermal Spread in an Animal ModelJournal of Endourology, 2005
- Efficacy of Absorbable Clips Compared with Metal Clips for Cystic Duct Ligation in Laparoscopic CholecystectomySurgery Today, 2003
- Laparoscopic cholecystectomy by ultrasonic dissection without cystic duct and artery ligatureSurgical Endoscopy, 2002
- Sealing of cystic duct with bipolar electrocoagulationSurgical Endoscopy, 2001
- Experimental comparison of the ultrasonically-activated scalpel to electrosurgery and laser surgery for laparoscopic useMinimally Invasive Therapy & Allied Technologies, 1997
- Incidence and nature of bile duct injuries following laparoscopic cholecystectomy: An audit of 5913 casesBritish Journal of Surgery, 1996
- Absorbable clips for cystic duct ligation in laparoscopic cholecystectomySurgical Endoscopy, 1996