Minimizing Tissue Damage in Electroosmotic Sampling
- 15 July 2010
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 82 (15) , 6370-6376
Abstract
Electroosmotic sampling is a potentially powerful method for pulling extracellular fluid into a fused-silica capillary in contact with the surface of tissue. An electric field is created in tissue by passing current through an electrolyte-filled capillary and then through the tissue. The resulting field acts on the counterions to the surface charges in the extracellular space to create electroosmotic fluid flow within the extracellular space of a tissue. Part of the development of this approach is to define conditions under which electroosmotic sampling minimizes damage to the tissue, in this case organotypic hippocampal slice cultures (OHSCs). We have assessed tissue damage by measuring fluorescence resulting from exposing sampled tissue to propidium iodide solution 16−24 h after sampling. Sampling has been carried out with a variety of capillary diameters, capillary tip-tissue distances, and applied voltages. Tissue damage is negligible when the power (current x potential drop) created in the tissue is less than 120 μW. In practical terms, smaller capillary i.d.s, lower voltages, and greater tissue to capillary distances lead to lower power.Keywords
This publication has 18 references indexed in Scilit:
- Minimizing Tissue Damage in Electroosmotic SamplingAnalytical Chemistry, 2010
- Electroosmotic Sampling. Application to Determination of Ectopeptidase Activity in Organotypic Hippocampal Slice CulturesAnalytical Chemistry, 2010
- Review of recent advances in analytical techniques for the determination of neurotransmittersAnalytica Chimica Acta, 2009
- Measurement of Region-Specific Nitrate Levels of the Posterior Chamber of the Rat Eye Using Low-Flow Push−Pull PerfusionAnalytical Chemistry, 2008
- Determination of ζ-Potential in Rat Organotypic Hippocampal CulturesBiophysical Journal, 2008
- Sub-microlitre dialysis system to enable trace level peptide detection from volume-limited biological samples using MALDI-TOF-MSThe Analyst, 2007
- Hypoosmolar conditions reduce extracellular volume fraction and enhance epileptiform activity in the CA3 region of the immature rat hippocampusJournal of Neuroscience Research, 2006
- Microfluidic Chip for Low-Flow Push-Pull Perfusion Sampling in Vivo with On-Line Analysis of Amino AcidsAnalytical Chemistry, 2005
- Organotypic slice cultures: a technique has come of ageTrends in Neurosciences, 1997
- In vivo microdialysis - a new approach to the analysis of neurotransmitters in the brainLife Sciences, 1987