Abstract
An analytical expression for HD3 (third harmonic distortion) due to the input-dependent, non-linear ON resistance of the MOS switch in a MOSFET-C sample and hold circuit is developed. The developed expression is suitable for hand calculation, and for a given target value of HD3, it can be used for an initial design of the MOS switch. The accuracy of the developed expression has been verified through simulation in 0.18 /spl mu/m and 0.25 /spl mu/m CMOS processes.

This publication has 3 references indexed in Scilit: