Anti-thrombogenic coatings for devices in neurointerventional surgery: Case report and review of the literature
Open Access
- 27 June 2019
- journal article
- review article
- Published by SAGE Publications in Interventional Neuroradiology
- Vol. 25 (6) , 619-627
Abstract
Background: Stent-assisted coiling and extra-saccular flow diversion require dual anti-platelet therapy due to the thrombogenic properties of the implants. While both methods are widely accepted, thromboembolic complications and the detrimental effects of dual anti-platelet therapy remain a concern. Anti-thrombogenic surface coatings aim to solve both of these issues. Current developments are discussed within the framework of an actual clinical case. Case description: A 33-year-old male patient lost consciousness while doing sport and was administered 500 mg acetylsalicylic acid on site. Computed tomography revealed a massive subarachnoid haemorrhage, and digital subtraction angiography showed an aneurysm of the right middle cerebral artery. Stent-assisted coiling using a neck bridging device with a hydrophilic coating (pCONUS_HPC) was considered as an appropriate approach. Another 500 mg acetylsalicylic acid IV was given. After the single anti-platelet therapy was seen to be effective, a pCONUS_HPC was implanted, and the aneurysm sac subsequently fully occluded using coils. No thrombus formation was encountered. During the following days, 2 × 500 mg acetylsalicylic acid IV daily were required to maintain single anti-platelet therapy, monitored by frequent response testing. Follow-up digital subtraction angiography after 13 days confirmed the occlusion of the aneurysm and the patency of the middle cerebral artery. Conclusion: A variety of ways to reduce the thrombogenicity of neurovascular stents is discussed. Hydrophilic surface coatings are a valid concept to improve the haemocompatibility of neurovascular implants while avoiding the use of dual anti-platelet therapy. Phosphorylcholine and phenox hydrophilic polymer coating are currently the most promising candidates. This concept is supported by anecdotal experience. However, formalised registries and randomised trials are currently being established.Keywords
This publication has 46 references indexed in Scilit:
- Preliminary experience with the Pipeline Flex Embolization Device: technical noteJournal of NeuroInterventional Surgery, 2014
- Stent-Assisted Coiling versus Coiling in Treatment of Intracranial Aneurysm: A Systematic Review and Meta-AnalysisPLOS ONE, 2014
- Risk of hemorrhagic complication associated with ventriculoperitoneal shunt placement in aneurysmal subarachnoid hemorrhage patients on dual antiplatelet therapyJournal of Neurosurgery, 2013
- Direct thrombin inhibitor-bivalirudin functionalized plasma polymerized allylamine coating for improved biocompatibility of vascular devicesBiomaterials, 2012
- Incidence of cerebral ischemic events after discontinuation of clopidogrel in patients with intracranial aneurysms treated with stent-assisted techniquesJournal of Neurosurgery, 2012
- Thromboresistant and endothelialization effects of dopamine-mediated heparin coating on a stent material surfaceJournal of Materials Science: Materials in Medicine, 2012
- The Efficacy of Nanoscale Poly[bis(trifluoroethoxy) phosphazene] (PTFEP) Coatings in Reducing Thrombogenicity and Late In-Stent Stenosis in a Porcine Coronary Artery ModelInvestigative Radiology, 2007
- Use of Heparin-coated Stents in Neurovascular Interventional Procedures: Preliminary Experience with 10 PatientsNeurosurgery, 2006
- Reduced thrombogenicity of nitinol stents—In vitro evaluation of different surface modifications and coatingsBiomaterials, 2006
- Influence of Stent Length and Heparin Coating on Platelet ActivationThrombosis Research, 1999