Surface analysis of an encapsulation membrane after its implantation in mini-pigs
Authors:
- Marie HenryMHMarie Henry
- Karin UlrichsKUKarin Ulrichs
- Vasily MoskalenkoVMVasily Moskalenko
- Michel BonneauMBMichel Bonneau
- Chantal KangCKChantal Kang
- Alain BelcourtABAlain Belcourt
- Patrick BertrandPBPatrick Bertrand
- 1 March 2007
- journal article
- Published by IOP Publishing in Biomedical Materials
- Vol. 2 (1) , S78-S89
Abstract
The biocompatibility of membranes aiming at being a part of a bioartificial pancreas has been tested. For that purpose, we have studied a polycarbonate membrane surface after its implantation in mini-pigs. The membranes were made hydrophilic by an argon plasma surface treatment followed by a dipping in a hydrophilic polymer solution. Two polymers were tested: polyvinylpyrrolidone (PVP) and hydroxypropylmethylcellulose (HPMC). To test their biocompatibility, an encapsulation device for pig Langerhans islets, with external membranes treated as described above, was implanted in different mini-pigs. The pigs received no further treatment. The devices were explanted after in vivo exposure and the membranes were analysed by XPS (x-ray photoelectron spectroscopy) and ToF-SIMS (time-of-flight secondary ion mass spectrometry). After this time, the substrate with the PVP or HPMC treatment was still detected on the different samples. The surface treatment signal, however, was attenuated. This is explained by the detection of other components partly covering the surface. XPS and ToF-SIMS analyses revealed the presence of biological molecules on the two faces of the membrane: the outside face in contact with the biological environment and the inside face in contact with the device. ToF-SIMS images show the inhomogeneity of the biological molecules on the membrane surface. In conclusion, biological molecules adhered to the encapsulation membrane surface after implantation but the surface treatments remained unaltered.Keywords
This publication has 9 references indexed in Scilit:
- Conformation Change of Albumin Adsorbed on Polycarbonate Membranes as Revealed by ToF-SIMSLangmuir, 2003
- Surface treatment of polycarbonate films aimed at biomedical applicationJournal of Biomaterials Science, Polymer Edition, 2003
- Imaging of Freeze-Fractured Cells with in Situ Fluorescence and Time-of-Flight Secondary Ion Mass SpectrometryAnalytical Chemistry, 2002
- Biomedical surface science: Foundations to frontiersSurface Science, 2002
- Characterization of Adsorbed Protein Films by Time-of-Flight Secondary Ion Mass Spectrometry with Principal Component AnalysisLangmuir, 2001
- ToF-SIMS quantification of polystyrene spectra based on principal component analysis (PCA)†Surface and Interface Analysis, 1997
- Adsorption of Polyelectrolyte Multilayers on Polymer SurfacesLangmuir, 1997
- Identification and Mapping of Phosphocholine in Animal Tissue by Static Secondary Ion Mass Spectrometry and Tandem Mass SpectrometryRapid Communications in Mass Spectrometry, 1996
- Interaction of ion beams with polymers, with particular reference to SIMSVacuum, 1986