A Simple Rapid Method for Measuring Liver Steatosis Using Bioelectrical Impedance
Authors:
- 2 March 2022
- journal article
- research article
- Published by International Institute of Anticancer Research in In Vivo
- Vol. 36 (2) , 570-575
Abstract
Background/Aim: Easy measurement of liver steatosis without pathological diagnosis may help improve donor surgery efficiency and increase the chances of organ donations. We analyzed the correlations between bioelectrical impedance (BI) in human livers, liver fat content, and pathological findings. Materials and Methods: Sixteen tumor-free liver specimens resected during elective oncological surgery were analyzed. All samples were stored in ice chilled saline before BI measurement. The BI measurement was performed using a device with the tetrapolar circuit method in which the current and voltage electrodes are independent. Liver cholesterol and triglyceride levels were investigated from the same specimen using the Soxhlet extraction method. Pathological findings were examined by counting the number of hepatocytes with fatty changes per high-power field. Results: The median liver steatosis percentage was 0.4%. The liver steatosis percentage was significantly correlated with the intrahepatic triglyceride content (r=0.82, p2 of 0.63 between the BI at 100 kHz and liver steatosis, indicating reasonable agreement (p<0.001). Conclusion: BI analysis is a simple, non-invasive method that can be easily applied to evaluate liver steatosis.Keywords
This publication has 15 references indexed in Scilit:
- Liver transplantation using fatty livers: Always feasible?Journal of Hepatology, 2011
- Bioelectrical Impedance Analysis for Evaluation of Donor Hepatic Steatosis in Living-Donor Liver TransplantationTransplantation Proceedings, 2010
- A Rapid and Reliable Means of Assessing Hepatic Steatosis In Vivo Via Electrical BioimpedanceTransplantation, 2009
- Hepatic Steatosis in Organ Donors: Disparity Between Surgery and Histology?Transplantation Proceedings, 2009
- Use of Bioelectrical Impedance Analysis to Assess Liver SteatosisTransplantation Proceedings, 2009
- In vivodetection of liver steatosis in rats based on impedance spectroscopyPhysiological Measurement, 2007
- When is steatosis too much for transplantation?Journal of Hepatology, 2006
- Assignment of steatotic livers by the Mayo model for end-stage liver diseaseTransplant International, 2005
- Electrical bioimpedance measurement during hypothermic rat kidney preservation for assessing ischemic injuryBiosensors and Bioelectronics, 2005