Correlation of Infrared Thermal Imaging Results with Visual Inspection and Current-Voltage Data of PV Modules Installed in Kumasi, a Hot, Humid Region of Sub-Saharan Africa
Author:
Open Access
- 18 October 2017
- journal article
- research article
- Published by MDPI AG in Technologies
- Vol. 5 (4) , 67
Abstract
In this study, a photovoltaic (PV) modules site installed from 1997 to 2017 (20 years of outdoor exposure) in the hot, humid region of Kumasi, Ghana in Sub-Saharan Africa was selected in order to study the aging phenomenon and rate of degradation due to long-term exposure. The main purpose of this work was to correlate the performance of 14 PV modules using data from infra-red thermal imaging (hot spot tests), current-voltage (I-V) tests and visual inspection. The modules were first visually inspected followed by electrical performance tests using an I-V curve tracer. Hot spot testing of each module was performed to enable further characterization. The results of the visual inspection using the United States National Renewable Energy Laboratory (NREL) checklist did not show any major observable defects. The results also show that the higher the temperature difference in the hot spot tests, the higher the rate of power degradation. Eleven modules failed the hot spot tests according to the criteria indicated in the literature. The average power degradation rate was 1.36%/year, which is above the industry-accepted range of 0.7–1.0%/year. The results provide evidence of a positive correlation between temperature difference and performance parameters such as power degradation (Pdeg), power performance factor (PPF) and power drop (Pdrop). The power performance factor for all 14 modules fell below the average 80% standard set by most manufacturers for modules operating within the 25-year warranty.Keywords
This publication has 13 references indexed in Scilit:
- Reliability and Degradation of Solar PV Modules—Case Study of 19-Year-Old Polycrystalline Modules in GhanaTechnologies, 2017
- Hotspots Detection in Photovoltaic Modules Using Infrared ThermographyMATEC Web of Conferences, 2016
- Performance and degradation analysis for long term reliability of solar photovoltaic systems: A reviewRenewable and Sustainable Energy Reviews, 2013
- Fault diagnosis of photovoltaic modules through image processing and Canny edge detection on field thermographic measurementsInternational Journal of Sustainable Energy, 2013
- Standards, Calibration, and Testing of PV Modules and Solar Cells2012
- Photovoltaic Degradation Rates—an Analytical ReviewProgress in Photovoltaics: Research and Applications, 2011
- Typical defects of PV-cells2010
- Optical degradation of long-term, field-aged c-Si photovoltaic modulesSolar Energy Materials and Solar Cells, 2005
- A comparison of the performance of different PV module types in temperate climatesSolar Energy, 2004
- Outdoor rating conditions for photovoltaic modules and systemsSolar Energy Materials and Solar Cells, 2000