Evaluation of Distal Femoral Rotational Alignment with Spiral CT Scan before Total Knee Arthroplasty (A Study in Iranian population).
- 1 April 2016
- journal article
- Vol. 4 (2) , 122-7
Abstract
Evaluating the landmarks for rotation of the distal femur is a challenge for orthopedic surgeons. Although the posterior femoral condyle axis is a good landmark for surgeons, the surgical transepicondylar axis may be a better option with the help of preoperative CT scanning. The purpose of this study was to ascertain relationships among the axes' guiding distal femur rotational alignment in preoperative CT scans of Iranian patients who were candidates for total knee arthroplasty and the effects of age, gender, and knee alignment on these relationships. One hundred and eight cases who were admitted to two university hospitals for total knee arthroplasty were included in this study. The rotation of the distal femur was evaluated using single axial CT images through the femoral epicondyle. Four lines were drawn digitally in this view: anatomical and surgical transepicondylar axes, posterior condylar axis and the Whiteside anteroposterior line. The alignment of the extremity was evaluated in the standing alignment view. Then the angles were measured along these lines and their relationship was evaluated. The mean angle between the anatomical transepicondylar axis and posterior condylar axis and between the surgical transepicondylar axis and posterior condylar axis were 5.9 ± 1.6 degrees and 1.6±1.7 degrees respectively. The mean angle between the Whiteside's anteroposterior line and the line perpendicular to the posterior condylar axis was 3.7±2.1 degrees. Significant differences existed between the two genders in these relationships. No significant correlation between the age of patients and angles of the distal femur was detected. The anatomical surgical transepicondylar axis was in 4.3 degrees external rotation in relation to the surgical transepicondylar axis. Preoperative CT scanning can help accurately determine rotational landmarks of the distal femur. If one of the reference axes cannot be determined, other reference axes can be used because of the good correlation between these landmarks.Keywords
This publication has 21 references indexed in Scilit:
- Computed tomographic evaluation of femoral component rotation in total knee arthroplastyIndian Journal of Orthopaedics, 2013
- How precise can bony landmarks be determined on a CT scan of the knee?The Knee, 2009
- Rotational alignment of the distal femur: A literature reviewOrthopaedics & Traumatology: Surgery & Research, 2009
- Rotational Position of Femoral and Tibial Components in TKA Using the Femoral Transepicondylar AxisClinical Orthopaedics and Related Research, 2008
- Torsion distale fémorale du genou : comparaison de la mesure par tomodensitométrie et par navigation peropératoire au cours des arthroplasties totales de genouRevue de Chirurgie Orthopedique Et Reparatrice de L'appareil Moteur, 2008
- Low reproducibility of the intra–operative measurement of the transepicondylar axis during total knee replacementActa Orthopaedica, 2004
- Computed tomography measurement of the surgical and clinical transepicondylar axis of the distal femur in osteoarthritic kneesThe Journal of Arthroplasty, 2001
- The posterior condylar angle in osteoarthritic kneesThe Journal of Arthroplasty, 1998
- Determining the Rotational Alignment of the Femoral Component in Total Knee Arthroplasty Using the Epicondylar AxisClinical Orthopaedics and Related Research, 1993
- The anatomy and functional axes of the femur.Journal of Bone and Joint Surgery, 1987