Cloth–Air Partitioning of Neutral Per- and Polyfluoroalkyl Substances (PFAS) in North Carolina Homes during the Indoor PFAS Assessment (IPA) Campaign
- 27 September 2023
- journal article
- research article
- Published by American Chemical Society (ACS) in Environmental Science & Technology
- Vol. 57 (40) , 15173-15183
Abstract
Partitioning of per- and polyfluoroalkyl substances (PFAS) to indoor materials, including clothing, may prolong the residence time of PFAS indoors and contribute to exposure. During the Indoor PFAS Assessment (IPA) Campaign, we measured concentrations of nine neutral PFAS in air and cotton cloth in 11 homes in North Carolina, for up to 9 months. Fluorotelomer alcohols (i.e., 6:2 FTOH, 8:2 FTOH, and 10:2 FTOH) are the dominant target species in indoor air, with concentrations ranging from 1.8 to 49 ng m-3, 1.2 to 53 ng m-3, and 0.21 to 5.7 ng m-3, respectively. In cloth, perfluorooctane sulfonamidoethanols (i.e., MeFOSE and EtFOSE) accumulated most significantly over time, reaching concentrations of up to 0.26 ng cm-2 and 0.24 ng cm-2, respectively. From paired measurements of neutral PFAS in air and suspended cloth, we derived cloth-air partition coefficients (Kca) for 6:2, 8:2, and 10:2 FTOH; ethylperfluorooctane sulfonamide (EtFOSA); MeFOSE; and EtFOSE. Mean log(Kca) values range from 4.7 to 6.6 and are positively correlated with the octanol-air partition coefficient. We investigated the effect of the cloth storage method on PFAS accumulation and the influence of home characteristics on air concentrations. Temperature had the overall greatest effect. This study provides valuable insights into PFAS distribution, fate, and exposure indoors.Keywords
Funding Information
- Division of Graduate Education (2020305405)
- Alfred P. Sloan Foundation (G-2017-9794, G-2020-13937)
- National Institute for Occupational Safety and Health (T42-OH008673)
This publication has 82 references indexed in Scilit:
- Improved Characterization of Gas–Particle Partitioning for Per- and Polyfluoroalkyl Substances in the Atmosphere Using Annular Diffusion Denuder SamplersEnvironmental Science & Technology, 2012
- Polyfluorinated Compounds in Serum Linked to Indoor Air in Office EnvironmentsEnvironmental Science & Technology, 2011
- Characterisation of human exposure pathways to perfluorinated compounds — Comparing exposure estimates with biomarkers of exposureEnvironment International, 2011
- An overview analysis of the time people spend outdoorsBritish Journal of Dermatology, 2011
- Polyfluorinated Compounds in Residential and Nonresidential Indoor AirEnvironmental Science & Technology, 2010
- Determination of Octanol−Air Partition Coefficients (KOA) of Fluorotelomer Acrylates, Perfluoroalkyl Sulfonamids, and Perfluoroalkylsulfonamido EthanolsJournal of Chemical & Engineering Data, 2009
- Semivolatile organic compounds in indoor environmentsAtmospheric Environment, 2008
- Irreversible sorption of trace concentrations of perfluorocarboxylic acids to fiber filters used for air samplingAtmospheric Environment, 2008
- Estimating Consumer Exposure to PFOS and PFOARisk Analysis, 2008
- Measuring and simulating particulate organics in the atmosphere: problems and prospectsAtmospheric Environment, 2000