Validity of the Actical Accelerometer Step-Count Function
Authors:
- Dale W. EsligerDEDale W. Esliger
- Adam ProbertAPAdam Probert
- Sarah Connor GorberSGSarah Connor Gorber
- Shirley BryanSBShirley Bryan
- Manon LavioletteMLManon Laviolette
- Mark S. TremblayMTMark S. Tremblay
- 1 July 2007
- journal article
- research article
- Published by Wolters Kluwer Health in Medicine & Science in Sports & Exercise
- Vol. 39 (7) , 1200-1204
Abstract
To assess the validity of the new Actical accelerometer step count function. Actical step counts were compared according to two criterion standards. 1) Eight Acticals were assessed using a mechanical shaker table under six different testing conditions. 2) Thirty-eight volunteers (aged 9-59 yr) wore eight Acticals and eight Actigraphs during treadmill walking (50 and 83 m.min(-1)) and running (133 m.min(-1)) for 6 min at each speed. Steps were counted during the second and fourth minutes of each speed by a trained observer. The correlation between Actical step counts and the mechanical shaker step counts was excellent (r = 1.0). Compared with visually counted steps, both the Actical and Actigraph step counts were significantly different at 50 m.min(-1); however, no significant differences were evident at 83 and 133 m.min(-1). The criterion-related validity correlations (r) for the Actical and Actigraph, respectively, were 0.73 and 0.52 at the slow walk condition and 0.99 and 0.99 at the normal walk and run conditions. The new step count function of the Actical accelerometer provides valid estimates of step counts at 83 and 133 m.min(-1) on a range of healthy participants.Keywords
This publication has 16 references indexed in Scilit:
- Technical Reliability Assessment of Three Accelerometer Models in a Mechanical SetupMedicine & Science in Sports & Exercise, 2006
- Commercially available pedometers: considerations for accurate step countingPreventive Medicine, 2004
- Validity of 10 Electronic Pedometers for Measuring Steps, Distance, and Energy CostMedicine & Science in Sports & Exercise, 2003
- Limits to the measurement of habitual physical activity by questionnairesBritish Journal of Sports Medicine, 2003
- Comparison of Pedometer and Accelerometer Accuracy under Controlled ConditionsMedicine & Science in Sports & Exercise, 2003
- Utility of Pedometers for Assessing Physical ActivitySports Medicine, 2002
- Dose-response issues concerning physical activity and health: an evidence-based symposiumMedicine & Science in Sports & Exercise, 2001
- Methodological Considerations for Researchers and Practitioners Using Pedometers to Measure Physical (Ambulatory) ActivityResearch Quarterly for Exercise and Sport, 2001
- Measurement of daily walking distance-questionnaire versus pedometerMedicine & Science in Sports & Exercise, 2000
- Accuracy of five electronic pedometers for measuring distance walkedMedicine & Science in Sports & Exercise, 1996