Precision and Reliability of 5 Platelet Function Tests in Healthy Volunteers and Donors on Daily Antiplatelet Agent Therapy
Authors:
Open Access
- 1 December 2014
- journal article
- Published by Oxford University Press (OUP) in Clinical Chemistry
- Vol. 60 (12) , 1524-1531
Abstract
Background: Anticoagulation protocols used during mechanical circulatory support call for titration of antiplatelet agents. We compared the precision and reliability of 5 platelet function tests in healthy volunteers and donors on daily antiplatelet therapy to distinguish their efficacy for titrating antiplatelet therapy. Methods: We assessed arachidonic acid–induced platelet function by light transmission aggregometry (LTA), Multiplate impedance aggregometry, VerifyNow, and platelet mapping by thromboelastography (TEG PM). We assessed ADP-induced platelet function by the same methods and flow cytometry. Forty healthy volunteers and 10–13 volunteers on daily aspirin and/or clopidogrel therapy were evaluated. We compared tests for intraassay precision, interassay precision (samples from 2 separate blood draws), and reliability coefficient. Results: For arachidonic acid–induced platelet aggregation in healthy volunteers, intra- and interassay CVs were ≤10% for all methods. Intra- and interassay precision among donors on daily aspirin was ≤30% for all methods except LTA (38% interassay CV) and TEG PM (95% intra-assay and 104% interassay CV). For ADP-induced platelet function, intra- and interassay precision was ≤10% and ≤30% for all methods. Only Multiplate demonstrated moderate or greater (R > 0.40) reliability coefficients for arachidonic acid–induced platelet function among all subjects. All methods of ADP-induced platelet function, except TEG PM, demonstrated substantial or greater (R > 0.60) reliability among all subjects. Conclusions: TEG PM is least suited to monitor effects of antiplatelet agents. Multiplate impedance aggregometry was the only method to demonstrate an acceptable reliability coefficient among healthy volunteers and donors on both aspirin and clopidogrel therapy.Keywords
This publication has 19 references indexed in Scilit:
- Consensus and Update on the Definition of On-Treatment Platelet Reactivity to Adenosine Diphosphate Associated With Ischemia and BleedingJACC, 2013
- Readmissions After Implantation of Axial Flow Left Ventricular Assist DeviceJACC, 2013
- Prospective Trial of a Pediatric Ventricular Assist DeviceNew England Journal of Medicine, 2012
- What is the optimal anticoagulation in patients with a left ventricular assist device?Interactive CardioVascular and Thoracic Surgery, 2012
- Low stroke rate and few thrombo-embolic events after HeartMate II implantation under mild anticoagulationEuropean Journal of Cardio-Thoracic Surgery, 2012
- Berlin Heart EXCOR Pediatric ventricular assist device Investigational Device Exemption study: Study design and rationaleAmerican Heart Journal, 2011
- Consensus and Future Directions on the Definition of High On-Treatment Platelet Reactivity to Adenosine DiphosphateJACC, 2010
- Whole Blood Multiple Electrode Aggregometry Is a Reliable Point-of-Care Test of Aspirin-Induced Platelet DysfunctionAnesthesia & Analgesia, 2009
- Complications in Patients With Ventricular Assist DevicesDimensions of Critical Care Nursing, 2008
- Aspirin Responsiveness in Healthy Volunteers Measured with Multiple Assay PlatformsClinical Chemistry, 2008