Comparison of BCF-10, BCF-12, and BCF-20 Scintillating Fibers for Use in a 1-Dimensional Linear Sensor
- 17 September 2013
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 60 (5) , 4015-4021
Abstract
One-dimensional fiber-bundle arrays may prove useful in a number of radiation sensing applications where radiation detection over large areas is needed. Tests have been performed to evaluate the light generation and transmission characteristics of 15-meter long, 10-fiber bundles of BCF-10, BCF-12, and BCF-20 scintillating fibers (Saint Gobain) exposed to collimated gamma-ray sources. The test set-up used one R9800 (Hamamatsu) photomultiplier tube (PMT) at each end, with a high-speed waveform digitizer to collect data. Time constraints were imposed on the waveform data to perform time-of-flight analysis of the events in the fiber bundles, eliminating spurious noise pulses in the high gain PMTs and also allowing 1-dimensional localization of interactions along the lengths of the fiber bundles. Measurements show that the spatial response of these three fibers is linear over at least 15-m lengths and that, with the equipment used here, the spatial resolution for events irradiating 1 cm of fiber (using a collimated source) ranges from 50 cm to 60 cm over the entire length of the bundles. The efficiency for detecting events varies along the length of the arrays, with the sensitivity at the midpoint (half of the distance) of an array ranging from ~ 2X to ~ 3X the efficiency at the ends, depending on the length of the fiber-bundle array and the self-absorption factor for each fiber's scintillation light. Compared to prior work, a 20-fold improvement in detection sensitivity has been shown for this technique, most likely due to improved optical coupling and improved signal analysis.Keywords
This publication has 22 references indexed in Scilit:
- A timing resolution model for scintillating fibers2011
- EPR study of radiation stability of organic plastic scintillator for cardiovascular brachytherapy Sr90–Y90 beta dosimetryApplied Radiation and Isotopes, 2005
- Particle tracking with scintillating fibersIEEE Transactions on Nuclear Science, 1996
- Direct reading measurement of absorbed dose with plastic scintillators—The general concept and applications to ophthalmic plaque dosimetryMedical Physics, 1996
- Conceptual design for a scintillating-fiber neutron detector for fusion reactor plasma diagnosticsReview of Scientific Instruments, 1995
- Scintillating-glass-fiber neutron sensorsNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1994
- Cerenkov light generated in optical fibres and other light pipes irradiated by electron beamsPhysics in Medicine & Biology, 1992
- High-resolution tracking with scintillating fibresNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1989
- Development of new scintillating fiber detectors for high energy physics applicationsIEEE Transactions on Nuclear Science, 1989
- Initial tests of a high resolution Scintillating Fibre (SCIFI) trackerNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1987